Specifications

Fan Blower Controls
Form, Fit and Functional OEM Replacement Parts
ICM Control Features and Applications Specifications Replaces
ICM270
Dual function fan delay timer
Controls the circulating fan in heat pump, A/C and forced air
systems
OFF delay purges ducts of residual air
ON delay allows air to reach the proper comfort level prior to
energizing the fan
Voltage:
18-30 VAC
Contact ratings:
Heat/cool speed
N.O.:
20 amps @ 240 VAC
N.C.:
10 amps @ 240 VAC
Time delays:
Blower ON delay:
30 seconds
Blower OFF delay:
90, 120, 150, 180
seconds
Evcon
:
2702-300
Rheem
:
47-22827-01
47-22827-81/82/83
47-22828-01/02
Robertshaw: 695-003
ICM271
Reliable solid state fan blower control
Specifically designed to replace popular gas furnace centers
Pin selectable blower delays
High power, relay output
Dual function fan delay timer
Controls the circulating fan in HP, A/C and forced air systems
OFF delay purges ducts of residual air
ON delay allows air to reach the proper comfort level prior to
energizing the fan
Voltage: 18-30 VAC
Contact ratings:
N.O.: 20 amps
N.C.: 10 amps
Time delays:
Heat ON delay: 75 seconds
Heat OFF delay: 105 seconds
Cool OFF delay: 90 seconds
Carrier:
302075-3
CES0110017
CES0110018
HH84AA010
HH84AA011
HH84AA012
HH84AA013/020
P771-7002
Robertshaw: 695-100
ICM272
Cooling control module with fan delay
Integral low voltage terminal board with field thermostat wiring
Electronic air cleaner output
High power, relay output
DC output for fan relays and 1st stage of electric heater control
Interlock circuitry prevents 2nd & 3rd stage electric heat
energization without proper fan operation
Voltage: 18-30 VAC
Contact ratings:
N.O.: 20 amps
N.C.: 10 amps
Time delay:
Blower OFF delay: 60 seconds
Carrier:
HK61GA001
HK61GA003
Texas Instruments: 2FD-1
ICM273
Solid state output
Silent operation, ”no clicking”
Controls the circulating fan in HP, A/C and forced air systems
OFF delay purges ducts of residual air
Voltage: 18-30 VAC
Output: 2 amps @ 240 VAC
Time delay:
Blower OFF delay: 60 seconds
EMI: 240000-969
ICM274
Microprocessor-based fan blower control
Built in humidity relay
Manually adjustable post-purge off delay from 60-240 seconds
Electronic air cleaner output
Voltage: 18-30 VAC
Outputs:
Y out: 1.5 amps
Fan: 2 amps
Elec. heat relay: 30 amps @ 240 VAC
Time delay:
Blower OFF delay: 60 seconds
EMI: 240-1764
ICM275
Heavy duty heat relay
Purges ducts of residual air
Integral short cycle protection
Voltage: 18-30 VAC
Contact ratings:
High: 20 amps @ 240 VAC
Low: 10 amps @ 240 VAC
Time delays:
Heat ON delay: 60 seconds
Heat OFF delay: 60-240 seconds
Cool OFF delay: 90 seconds
Carrier: CES0110019,
HH84AA001
HH84AA003
HH84AA005
HH84AA009
HH84AA014
HH84AA015
HH84AA021
Robertshaw: 695-101
ICM276
Microprocessor-based fan blower
Inducer fan outputs
Controls the circulation fan in gas/heat and A/C systems
OFF delay purges ducts of residual air
Voltage: 18-30 VAC
Outputs:
Fan: 20 amps @ 240 VAC
Inducer fan: 2 amps
Time delays:
Heat ON delay: 60 seconds
Heat OFF delay: 120, 150, 180 seconds
Cool OFF delay: 60 seconds
Carrier: HK51GA003
Rheem:
47-23619-02
47-23619-03
Robertshaw:
457-23619-03
RS100-833-02
ICM277
Microprocessor-based fan blower
For circulating fan in heat pump, A/C and forced air systems
Voltage: 18-30 VAC
Contact ratings:
N.O.: 20 amps
N.C.: 10 amps
Time delays:
Blower ON: 7 seconds
Blower OFF: 65 seconds
Goodman:
B1370735S
PCBFM131S
ICM offers low cost, form, fit and functional replacement fan blower controls for many popular OEM models. Our
fan blower controls monitor safety switches, provide on and off delays and control the speed of the fan in heat
pumps, and in air conditioning and forced air systems according to the logic of the original board.
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
25