Specifications
Motor Protection Controls
3-Phase Temperature Monitor
ICM Control Features and Applications Specifications Replaces
ICM441
Protects Against:
• Under voltage
• Over temperature
• Power interruptions
• Rapid short cycling
• Shorted temperature sensor
• Open temperature sensor
• Control duty, SPST relay layout
• Anti-short cycle time delay, 4 minutes (nominal)
• 1-second manual bypass
• Voltage: 120 or 208/240 VAC
• Frequency: 50-60 Hz
• Output:
• Relay: SPST
• N.O.: 6 amps resistive
• Dimensions: 3.25” x 3” x 1.25”
• Bristol: 241680
• Copeland:
071-0376-01, 071-0376-02
071-0397-00, 071-0397-01
071-0424-00, 071-0424-01
071-9800-00, 071-9800-01
• Mars:
37300, 37302. 37304,
37306, 37322
• Texas Instruments:
15AA1600 B, 15AA1600 C
15AA1603 B, 15AA1603 C
31AA1600 E, 31AA1606 E
Single Phase Motor Protection
ICM Control Features and Applications Specifications Replaces
ICM491
• Low cost single phase motor protection
• Built in anti-short cycle protection
• Detects high/low voltage conditions
• Helps prevent rapid system recycling
• LED indicators:
• Green for normal conditions
• Red for fault
• Heavy duty SPDT, isolated relay output
• Interrogation delay prevents nuisance trips: 5 seconds
• Voltage: 95-270 VAC
• Output:
• Relay: SPDT
• N.C./N.O.: 5 amps
• Time delay range: Adjustable
6-600 seconds
• Dimensions: 3.25” x 3” x 1.25”
• A-1: EAC-401, EAC-402
EAC-403, EAC-404
• Diversified: CV-100-RS
CV-200-RS15
CV-200-RS20
• Wagner/DiversiTech:
DSP-1
ICM492
• Protects against over and under voltage, and rapid short
cycling caused by transient faults and power interruptions
• Easy-view, backlit digital display
• RMS voltage monitoring
• Adjustable voltage set point
• Adjustable over voltage setting
• Adjustable under voltage setting
• Adjustable anti-short cycle time delay
• Adjustable response time
• Control mode
• 5-fault memory
• Universal line voltage input
• Heavy duty SPDT relay output
• Universal control voltage input (for integrating a thermostat)
User adjustable settings:
• Voltage set point: 80-300 VAC
• Anti-short cycle time delay: 0-720 sec.
• Over voltage setting: 5-25%
• Under voltage setting: 5-25%
• Control mode: On and Off
• Response time: 0.1-10 seconds
Inputs:
• Line voltage: 80-300 VAC
• Frequency: 50-60 Hz
• Accuracy: ±2%
• Low power consumption:
• Maximum 50 mA @ 120V
• Maximum 100 mA @ 240V
• Control voltage: 24-240 VAC
Output:
• Type: Dry relay contacts
• Form: SPDT
• Relay contact ratings:
• N.C. contacts: 10A resistive
@ 277 VAC
• N.O. contacts: 10A resistive
@ 277 VAC
Mechanical:
• Case dimensions: 3”L x 3.2”W x 1.35”H
• Unit weight: 0.36 lbs.
• Wagner/DiversiTech:
DSP-1
ICM515
• Easy installation
• Low cost, high performance
• Weatherproof housing
• Rugged, reliable
• Protects against:
• Lightning power surges
• Voltage surges from air conditioners, generators, motors
• Service voltage: 120-240 VAC,
single phase
• Max. surge current: 24,000 amps
• Max. energy dissipation: 240 Joules
• Installation point:
• Electrical panel
• Electrical disconnect
• AC protection modes: Line-line,
line-ground
• Dimensions: 1.75” x 1.62” x 0.75”
• Ditek: DTK-120-240CM
• Supco: SCM
ICM516
• Type 2 surge protective device
• UL Listed
• Easy installation
• Low cost, high performance
• Rugged, reliable
• Protects against:
• Lightning power surges
• Voltage surges from air conditioners, generators, motors
• Limited Lifetime Protection Warranty
• Service voltage: 120-240 VAC,
single phase
• Max. surge current: 100,000 amps
• Max. energy dissipation: 1,020 Joules
• Installation point:
• Electrical panel
• Electrical disconnect
• AC protection modes: Line-line,
line-ground
• Dimensions: 2.75” x 4.75” x 1.75”
• Supco: SCM Plus,
SCM150
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
17