Innovative HVACR control solutions Our products are Quality-Built in the U.S.A.
About ICM Controls ICM Controls World Headquarters ICM Controls leads the HVACR industry in the manufacture of electronic controls. We have achieved this position through product and process innovation, and we strive to maintain this position through extensive capitalization, focusing on our greatest manufacturing strength: true vertical integration. The ICM Controls manufacturing plant, located in North Syracuse, New York, is one of the most vertically integrated facilities in the country.
4 Table of Contents Motor Protection Controls............ 15 ICM Cross Reference HVACR Controls..................................................6 SimpleComfort® Thermostats..............................7 Timers – Delay on Make................... 8 ICM100................................................................8 ICM100F..............................................................8 ICM101................................................................8 ICM101F......................................
Table of Contents SimpleComfort® Thermostats 5 Dryout/New Construction Thermostats SimpleComfort® Thermostats Introduction............................ 36-37 SimpleComfort® Thermostats Quick Reference.................... 38-39 SimpleComfort® Standard • General Features........................... 40 Non Programmable Thermostats SimpleComfort® SC1001......................................................... 41 SimpleComfort® SC1001V.......................................................
Cross Reference 6 HVACR CONTROLS REPLACEMENT MODEL ICM P/N REPLACEMENT MODEL CONDENSATION CONTROL/ALARM Water Guard: 401475 ICM340 DELAY ON MAKE TIMERS ICM P/N REPLACEMENT MODEL ICM P/N DELAY ON BREAK TIMERS (continued) DUTY CYCLE CONTROLS Supco: TD733W (18-30v) ICM200F Carrier: HN67ZA012A ICM305 Supco: TD735 (18-30v) ICM201 SSAC: ESDR, TSDR Series ICM305 Supco: TD735W (18-30v) ICM201F SSAC: ESDR, TSDR Series ICM306 A-1: 7061 ICM103 Supco: TD73W ICM203F A-1: EAC-701-ADJ A-1: EAC-
Cross Reference 7 HVACR CONTROLS REPLACEMENT MODEL ICM P/N GAS IGNITION CONTROLS Honeywell: S8610U (and compatible Camstat, Fenwal, HSC, Penn-Johnson, Robertshaw and White Rodgers models) Honeywell: S8910U-1000 ICM290A Carrier: LH33WZ510 REPLACEMENT MODEL ICM P/N REPLACEMENT MODEL ICM P/N MOTOR STARTERS/RAPID START (continued) UNIVERSAL MOTOR STARTING RELAYS Kickstart: KS1 ICM805 Supco: SUPR, APR5 Kickstart: TO5, KS8 ICM803 ICM283 MARS: 32701, 35701 ICM855 OIL BURNER PRIMARY CONTROL IC
8 Timers Delay on Make Timers – Ideal for Compressor Staging APPLICATIONS TIMING DIAGRAM Ideal for compressor staging and stagger starting multiple motors and other equipment. Helps to reduce power surges. MODE OF OPERATION When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes. Delay on Make Timers ICM Control Features and Applications Specifications ICM100, 100F, 101, 101F • Higher 1.
Timers 9 Delay on Break Timers (Anti-Short Cycle Protection) APPLICATIONS TIMING DIAGRAM “Anti-short cycle” “ON delay on break” Helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short cycling of compressors. MODE OF OPERATION Upon application of power, the load is energized. When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins.
10 Timers Delay on Break Timers (continued) ICM Control Features and Applications Specifications Replaces • Voltage: 18-240 VAC • 1 amp • 10 amp inrush • Frequency: 50-60 Hz • Adjustable time delays: • 3 or 5-minute fixed or 10-minute adjustable time delay • Holding current minimum: 40 mA • Dimensions: 2” x 2” ICM207, 208, 209 • • • • • Universal voltage operation Helps prevent scroll compressor reversal Fast response time: 16 ms Compressor lockout/anti-short cycle timer Eliminates relay chatter due
Timers 11 Random Start Timers APPLICATIONS TIMING DIAGRAM ”Delay on make/delay on break” Initiate Switch Closed Ideal for use in compressor staging and to stagger-start multiple rooftop units. Helps to reduce power surges. No need to wait for the 5-minute delay typical of delay on make timers. Initiate Switch Open or Loss of Power Input Voltage 0V MODE OF OPERATION Upon application of power, the delay on make period begins. Once the delay is complete, the unit energizes.
12 Timers Multimode Digital Timers Versatile, Simple, Accurate ICM Control Features and Applications ICM500/501/502/503/504/505 • • • • • • • • • • • Multi-mode, selectable time delay ranges Crystal timing accuracy Microprocessor controlled 4 single and two dual timing modes • DOM, DOB, interval, single shot • DOM/DOB and repeat cycle Easy to select, switch-settable delays Bright LEDs indicate input and output Switch-settable time delays: 1 to 1,023 seconds or minutes in multiples of 0.
Freeze Protection 13 Freeze Protection Modules APPLICATIONS WIRING DIAGRAM The ICM308/309/310 are low cost, fixed, single setpoint temperature controls that provide freeze protection.
14 Compressor Protection Compressor Protection Module APPLICATION TIMING DIAGRAM The ICM221 is a low cost compressor protection module that monitors safety switch inputs and provides anti-short cycle protection. T MODE OF OPERATION Upon a Y call from the thermostat, the compressor contactor is energized (T) after the selected delay on make time, given all safety switches are closed and the unit is not in the anti-short cycle period.
Motor Protection Controls 15 ICM’s line voltage monitors continuously monitor incoming line voltage to provide superior motor protection from premature failure and damage due to voltage unbalance, high and low voltages, phase loss, phase reversal, faulty power, incorrect sequencing and/or rapid short cycling. Some models include LED indicators or LCD diagnostic displays to indicate the current system condition.
16 Motor Protection Controls Phase Loss and Reversal Protection • Ultra Low Cost ICM Control Features and Applications Specifications ICM408 • Reliable 3-phase protection for single side • Monitors for phase reversal, phase loss, unbalance % and high/low voltage • Bright LED indicators for ON and FAULT • High/low voltage cut-out: • High voltage cut-out setpoint: +12% • Low voltage cut-out setpoint: -12% • Highly reliable passive electronics • Power/phase loss detection: within 100 ms • User selectable
Motor Protection Controls 17 3-Phase Temperature Monitor ICM Control Features and Applications ICM441 Protects Against: • Under voltage • Over temperature • Power interruptions • Rapid short cycling • Shorted temperature sensor • Open temperature sensor • Control duty, SPST relay layout • Anti-short cycle time delay, 4 minutes (nominal) • 1-second manual bypass Specifications • Voltage: 120 or 208/240 VAC • Frequency: 50-60 Hz • Output: • Relay: SPST • N.O.: 6 amps resistive • Dimensions: 3.
18 Universal Motor Starting Relay Series UMSR APPLICATIONS WIRING DIAGRAM ICM’s new Universal Motor Starting Relay incorporates patented differential voltage sensing and a non-positional mounting configuration to offer a single replacement for all standard potential relays. Standard Wiring Diagram Alternative Reduced Arcing Configuration Great way to reduce inventory. Ideal for A/C, commercial refrigeration, heat pump or any single-phase motor application up to 10 HP.
Motor Speed Controls 19 Comfort Control Center Applications Wiring Diagram The award-winning CC750 Comfort Control Center works with your existing single-phase A/C or Heat Pump to more effectively remove moisture from the air. Provides enhanced comfort and improved indoor air quality with greater system efficiencies. Generates warmer air discharge temps for winter months in heat pump applications. Converts an inverter or standard grade PSC or shaded pole motor to a variable speed motor.
20 Motor Starters ICM803 and ICM805 - The Current Advantage “EXTENDS THE LIFE OF YOUR COMPRESSOR” By monitoring the compressor current upon start-up, RapidStart® is able to engage the hard start capacitor for precisely the correct amount of time, ensuring maximum starting torque without the risk of supplying too much current into the start winding. A timed safety circuit is provided in the event the motor fails to start within 2 seconds. Current sensing hard start precisely increases starting torque.
Motor Starters 21 ICM855 and ICM856 • PTCR Hard Start Capacitors ICM Controls Features and Applications ICM855 • • • • Increases torque up to 300% Positive Temperature Coefficient (PTC) technology Easy to install Low cost motor starting device ICM856 • • • • Increases torque up to 500% Positive Temperature Coefficient (PTC) technology Easy to install Low cost motor starting device Specifications Replaces • Voltage: 115-288 VAC • Capacitor: 43-52 Mfd, 330 V • Range: 1/2 to 10 HP (up to 1 1/2 HP reco
22 Motor Starters ICM860 - Voltage Sensing ICM’s differential voltage sensing products employ patented circuitry which monitors differential compressor auxiliary voltage, determines the state of the motor and precisely engages and disengages the start capacitor. A timed safety circuit is provided in the event the motor fails to start within 2 seconds.
Motor Starters HARD START RapidStart® “Current Sensing” Comparison Self Adjusting Uses Current Differential Technology Differential Current Relay 23 SOFT START Potential Relay PTCR Devices Timing Devices ICM RAPIDSTART® KICKSTART Conventional 3-Wire Relay & Capacitor Kit GEMLINE HS600 & HS650 MARS 32701 & 32702 ROBERTSHAW 600-052 & 600-057 SUPCO SPP5, SPP6, SPP7 WATSCO WSX-5, WSX-6 YES NO NO NO NO SUPCO SPP8 WATSCO WSX-1 YES NO NO NO NO Not Required YES YES NO NO Two Wires, Non-P
24 Fan Blower Controls Fan Blower • Off Delay on Break APPLICATIONS TIMING DIAGRAM ”OFF delay on break” Controls the circulating fan in heat pump, air conditioning and forced air systems. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency. MODE OF OPERATION Power must be applied before and during the time delay period.
Fan Blower Controls 25 ICM offers low cost, form, fit and functional replacement fan blower controls for many popular OEM models. Our fan blower controls monitor safety switches, provide on and off delays and control the speed of the fan in heat pumps, and in air conditioning and forced air systems according to the logic of the original board.
26 Furnace Controls ICM offers low cost, form, fit and functional replacement furnace controls for many popular OEM models. Our furnace controls come standard with many safety features including 100% gas shutoff in case of ignition failure.
Furnace Controls 27 Furnace Control Modules ICM Control Features and Applications ICM289 • Controls inducer fan motor, blower fan and monitors limit switches • Microprocessor based design • Functions with all 24 VAC thermostats ICM291 • Direct Spark Ignition (DSI) control board • Microprocessor-based • Controls combustion, blower and indoor motors; spark ignitor and the gas valve • Monitors timing, trial for ignition, flame sensing and lockout • 100% lockout safety feature • Compatible with LP or Natura
28 Furnace Controls Furnace Control Modules ICM Control Features and Applications Specifications • • • • • • • Replaces ENVIRONMENT • Ambient Temperature – Operating: -40ºF to 176ºF – Storage: -40ºF to 185ºF • Humidity: 5% to 95% R.H. (non-condensing) @ +55ºF • Vibration: 13.8Hz @ 0.
Gas Ignition Controls ICM293 • Intermittent Pilot Gas Ignition Control Module • For use with intermittent pilot boilers, furnaces and other heating appliances • Microprocessor-based • Monitors timing, trial for ignition, flame sensing and lockout • Remote flame sensing • 100% lockout safety feature • Compatible with LP or Natural Gas • Status LED for fault codes to aid in troubleshooting ICM294 • Intermittent Pilot Gas Ignition Control Module • For use with intermittent pilot boilers, furnaces and other he
30 Oil Burner Primaries Intermittent Ignition ICM Controls Application ICM’s 1500 Series Intermittent Ignition Oil Primary Controls come standard with patented energy transfer technology that ensures the fuel valve and pump will only be energized if the control is functioning properly. Features a solid state flame sensing circuit, LED to indicate system lockout, an enclosed safety switch and an external reset button. Form, fit and functional replacement for popular competitive models.
Defrost Controls 31 Form, Fit and Functional OEM Replacement Parts ICM Control Features and Applications ICM300 • • • • • • • • Replacement for OEM Type 621 Low cost, time and temperature defrost HOLD input tracks compressor run times Time and temperature terminate 10-minute fixed defrost time Pin-selectable intervals: 30/60/90 minutes Test pins reduce test time by 256x Stable pin post construction Specifications • Voltage: 18-30 VAC • Frequency: 50-60 Hz • Output: • Relay, SPST • N.O.
32 Defrost Controls Form, Fit and Functional OEM Replacement Parts (continued) ICM Control Features and Applications Specifications ICM316 • • • • • • • Replacement for Trane 21C142827G01 Low cost, time and temperature defrost Time and temperature terminate Pin-selectable intervals: 50/70/90 minutes Test pins reduce test time by 256x High power output (1/2 HP fan @ 240 VAC) Strip heat, reversing valve outputs (24 VAC, 1 amp) ICM317 • • • • • • Anti-bang reversing valve feature Select 0 or 3 minute a
Condensation Controls 33 Prevent Overflowing of an Evaporator Condensation Pan APPLICATION ICM’s condensate control systems protect your cooling and refrigeration equipment by detecting and preventing overflows in the evaporator condensation pan due to slow and/or blocked drains or pump failure. These reliable, low cost controls come with fixed or adjustable delays to eliminate nuisance trips and lockouts. Use in conjunction with our audible alarm to quickly alert you to an ensuing condensate problem.
34 Head Pressure Controls Head Pressure/Low Ambient Fan Controls ICM Control Features and Applications Specifications ICM325HN (120-480 VAC) ICM325HNV (600 VAC) • Integral heat pump bypass circuitry allows electronic bypass of speed control • Eliminates overshoots common to on/off and pressure switch controls • Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions • Hard start, low temperature cutoff, isolated 24 VAC supply • Controls up to
Head Pressure Controls/Accessories 35 Head Pressure/Accessories ICM Control Features and Applications ACC-OE-03 (Outdoor Enclosure) Specifications NEMA 3R rated • Rugged steel construction • Easy to mount • Helps to protect controls from harsh environmental conditions such as temperature, shock, humidity and vibration • Ideal for use with ICM head pressure controls • Dimensions: 4.25” x 6.25” x 6.
36 SimpleComfort® Thermostats • Introduction SimpleComfort Thermostats • • • • • • • ® Programmable & non-programmable models A model for every situation Sleek new footprint Large display Soft-touch controls Simple installation Available with custom logo All features and specifications subject to change without notice. Visit www.icmcontrols.com to find all of our latest products, sell sheets and wiring diagrams Phone Customer Service Fax Application Assistance 315.233.5266 315.233.5282 800.365.
37 Visit www.icmcontrols.com to find all of our latest products, sell sheets and wiring diagrams All features and specifications subject to change without notice. Application Assistance Customer Service Fax Phone 800.365.5525 315.233.5282 315.233.
38 SimpleComfort® Thermostats • Quick Reference SC2201VL SC2000L SC2311L Non-Programmable Thermostats Heat Only Thermostats Fan Coil Thermostats SC1600L: 1-stage heat, battery, no fan output SC1600VL: 1-stage heat, battery, no fan output, vertical SC1800L: 1-stage heat, battery SC1800VL: 1-stage heat, battery, vertical SC700V: 4-pipe heat/cool, 3-speed fan, auto changeover SC710V: 4-pipe heat/cool, 3-speed fan, manual changeover SC900V: 2 or 4-pipe, 3-speed fan, auto or manual changeover Cool Only Th
SimpleComfort® Thermostats • Quick Reference SC5011 SC5211 39 SC5812 Programmable Thermostats Heat/Cool Thermostats Multi-Stage Thermostats SC3000L: 1-stage heat/cool, battery SC3001L: 1-stage heat/cool, hardwired SC3010L: 1-stage heat/cool, dual powered SC5010: 1-stage heat/cool, auto changeover, dual powered, PRO series SC5011: 1-stage heat/cool, auto changeover, hardwired, PRO series SC5811: 2-stage heat/cool, auto changeover, hardwired, PRO series SC5812: 3-stage heat, 2-stage cool, auto changeo
40 SimpleComfort® Standard • General Features Simple to install. Simple to operate. Simply dependable. SimpleComfort® means simple control for year-round comfort and energy savings. These elegantly designed thermostats are extra rugged, highly reliable and accurate—ready for many years of worry-free operation. Simply perfect for residential or light commercial new construction or replacement. Easy, intuitive operation makes it simple to match temperature to any family’s lifestyle.
SimpleComfort® Standard Thermostats 41 Standard Non–Programmable Thermostats ICM Control Features and Applications SC1001 • • • • Low cost, electronic, heat/cool thermostat ICM patented Thermal Intrusion Barrier Easy “slide-bar” temperature adjustment Easy-view adjustment scale SC1001V • • • • • Low cost, electronic, heat/cool thermostat ICM patented Thermal Intrusion Barrier Easy “slide-bar” temperature adjustment Easy-view adjustment scale Vertical design for easy J-box installations SC1600L • • •
42 SimpleComfort® Standard Thermostats Standard Non–Programmable Thermostats ICM Control Features and Applications SC1901L • • • • • • Single-stage cool only thermostat ICM patented Thermal Intrusion Barrier Large backlit LCD display Hardwired Remote sensor compatible Compatible with A/C systems SC1901VL • • • • • • • Single-stage cool only thermostat ICM patented Thermal Intrusion Barrier Large backlit LCD display Hardwired Remote sensor compatible Compatible with A/C systems Vertical design for easy
SimpleComfort® Standard Thermostats 43 Standard Non–Programmable Thermostats ICM Control Features and Applications Specifications • • • • • • • • • • • • • • RC, RH, C, W, Y, O, B, G • Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • Temperature control ranges: 45°F to 90°F, Accuracy ± 1°F R, C, Y1, W2, O, B, G, E • Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • Temperature control ranges: 45°F to 90
44 SimpleComfort® Standard Thermostats Standard Programmable Thermostats ICM Control Features and Applications Specifications Terminations • Electrical Rating: • 24 VAC (18-30 VAC) For single-stage heat/cool or single-stage heat pump • 1 amp maximum per terminal 7-day, 5-2-day and 5-1-1-day programming • 3 amp maximum total load ICM patented Thermal Intrusion Barrier • Easy access terminal block New SimpleSet™ Target Programming technology Large display with backlight • Temperature control ranges: 45°F
SimpleComfort® PRO • General Features 45 Simp e to nstall and operate enhanced quality features Simplicity is in its name. ICM Controls SimpleComfort® PRO thermostats feature innovation and technology that delivers measurable value, simplifies installation and increases profitability.
46 SimpleComfort® PRO – Non-Programmable PRO Series Non-Programmable Thermostats ICM Control Features and Applications Specifications Terminations • Electrical Rating: • 24 VAC (18-30 VAC) For single-stage heat/cool or single-stage heat pump • 1 amp maximum per terminal ICM patented Thermal Intrusion Barrier • 4 amp maximum total load ICM SimpleSetTM Target Programming • Easy access terminal block (configuration mode only) Large display with backlight • Temperature control ranges: 45°F to 90°F, Dual po
SimpleComfort® PRO – Programmable 47 PRO Series Programmable Thermostats ICM Control Features and Applications Specifications RC, RH, C, W/O/B, Y, G, S1, S2 • Electrical Rating: • 24 VAC (18-30 VAC) For single-stage heat/cool or single-stage heat pump • 1 amp maximum per terminal 7-day, 5-2-day and 5-1-1-day programming • 4 amp maximum total load ICM patented Thermal Intrusion Barrier • Easy access terminal block ICM SimpleSetTM Target Programming Large backlit LCD display • Temperature control ranges
48 SimpleComfort® Fan Coil Thermostats Fan Coil Thermostats ICM Control Features and Applications Specifications SC700LV/SC700V • 4 pipe heat/cool • 3 speed fan • Auto changeover • 24 VAC (SC700LV) and 120-240 VAC (SC700V) versions available • Remote room temperature sensor (Optional: Order ACC-RT103) • Horizontal model available • UL Listed SC710LV/SC710V • 4 pipe heat/cool • 3 speed fan • Manual changeover • 24 VAC (SC710LV) and 120-240 VAC (SC710V) versions available • Remote room temperature senso
Dryout / New Construction Thermostats 49 The SC045 to SC075 series thermostats are low-cost, single setpoint thermostats intended for use as temporary devices to provide heating or cooling to allow drywall to dry during construction. They also can be used as a low ambient cutoff switch.
50 SimpleComfort® Thermostat Accessories Wall Plate SimpleSet™ Transfer Cable Need more wall coverage? Choose an ICM insulated wall plate. Program each thermostat in seconds!!! The fast, easy solution for hiding wall problems.
Selling Tools, Merchandising & Displays 51 ICM offers a wide variety of selling tools, and displays. Please contact your ICM Controls sales representative for more information. Part No.
52 Custom Logo Program • Request Form SimpleComfort® Thermostats Custom Logo Request Form LIM30-6 See complete instructions on Page 56 of this catalog. Fax to: (315) 233-5282 The complete custom logo request form is available on the home page of our web site at www.icmcontrols.com On the ICM home page, below “What’s New” click on “Custom Logo Form.” When the document appears, either print it or save it to your desktop. Note: Adobe Acrobat Reader is required.
Custom Logo Program • Sample Fonts 53 Contractor can choose from any of the following fonts for their logo Enter font number in provided box on request form (lower left). Copyright© ICM Controls. All rights reserved. No part of this catalog may be reproduced, stored in a retrieval system or transmitted in any form, by any means, electronic, mechanical, photocopying or otherwise, without the express written consent of the publisher. SIMPLECOMFORT® is a registered trademark of ICM Corporation. Visit www.
54 Custom Logo Program • Instructions SimpleComfort® Custom Logo Thermostats Ordering Recommendations 1. Read entire Custom Logo Request Form prior to completing it: • If you do not understand something, contact your ICM representative • ANY modifications to a previous “signed off” logo require a new request form 2.