DELUXE PROGRAMMABLE THERMOSTATS User's Manual Menu Driven Display Fully Programmable 24 VAC with Worry-Free Memory Storage English, Spanish or French Display Option 110-1023C Two Year Warranty
4 How do I change the time of day and day of the week? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU From the main screen press MENU. SET AT 78 MENU BACK DAY / TIME FAN USER SETTINGS INSTALLER SETTINGS HOME Use the UP or DOWN arrows to highlight DAY/TIME. Press SELECT. SELECT Use the UP or DOWN arrow to highlight DAY, HOUR or MINUTES. Press SET.
How do I turn on the heating or cooling cycles? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU From the main screen press MENU. SET AT 78 MENU PROGRAM Use the UP or DOWN arrows to highlight HEAT/COOL. Press SELECT. HEAT / COOL DAY / TIME FAN HOME MORE SELECT Use the UP or DOWN arrows to highlight HEAT, COOL or AUTO. Press SELECT. The SELECT button will turn on or off the desired cycle. You do not have to turn off HEAT to turn on COOL.
6 How do I cycle the fan? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU From the main screen press MENU. SET AT 78 Use the UP or DOWN buttons until FAN is highlighted. Press SELECT. MENU PROGRAM HEAT / COOL DAY / TIME FAN MORE Use the UP or DOWN buttons to highlight FAN settings. Press SELECT. Three choices are available: FAN PROGRAM FAN SETTINGS ON will turn the fan on continuously.
How do I temporarily change the temperature? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU SET AT 78 From the main screen, press the UP or DOWN button. The screen will change to the following. SET TEMPERATURE AT 70.0˚ Use the UP or DOWN button to adjust to the desired temperature. This is a temporary 3-hour hold or until the next programmed event, whichever is shorter. For a longer duration see page 9. F UNTIL 6:29 PM HOME SET TEMP SET AT 70°F UNTIL 6:29 PM 70.
8 Can I set a temporary adjustment for longer than 3 hours? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU Yes you can! Press the HOLD TEMP button. The following screen appears. SET AT 78 HOLD SETTINGS Press the DOWN button to highlight TEMPORARY HOLD. Press SELECT. PERMANENT HOLD TEMPORARY HOLD VACATION HOLD HOME SELECT TEMPORARILY AT 70.0˚ The temperature should be highlighted. Press the UP or DOWN button to adjust the temperature. Press SET TEMP.
Can I set the thermostat to hold one temperature indefinitely? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU You can do that too! From the main screen press the HOLD TEMP button. The following screen appears. SET AT 78 HOLD SETTINGS The PERMANENT HOLD feature should be highlighted. If it is not, use the UP or DOWN arrow to highlight it. Press SELECT. PERMANENT HOLD TEMPORARY HOLD PERMANENTLY AT VACATION HOLD HOME SELECT 70.
10 How do I set the Vacation Mode? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU Take a trip and don’t worry about the temperature! From the main screen press the HOLD TEMP button. The following screen appears. SET AT 78 HOLD SETTINGS Use the UP or DOWN arrow to highlight the VACATION HOLD feature. Press SELECT. PERMANENT HOLD TEMPORARY HOLD VACATION HOLD HOME SELECT VACATION SETTING The temperature should be highlighted. Use the UP or DOWN arrow change to the desired temperature.
How do I program my thermostat? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU SET AT 78 From the main screen press the MENU button. MENU Use the UP or DOWN button to highlight PROGRAM. Press SELECT. PROGRAM HEAT / COOL DAY / TIME FAN HOME MORE SELECT SELECT PROGRAM DAYS MON TO SUN MON TO FRI SAT TO SUN MONDAY MAIN MENU MORE SELECT You can select a variety of programming. Make your selection and press SELECT. MON-SUN allows every day to be set the same.
12 How do I program my thermostat? (Con’t.) MONDAY PROGRAM WAKE MORN EVE NIGHT 06:00A 08:30A 04:30P 10:30P MAIN MENU HEAT 70.0 62.0 70.0 62.0 COOL 78.0 85.0 78.0 82.0 The time for the first event should be highlighted. Use the UP or DOWN key to change the time. Press SET TIME. SET TIME MONDAY PROGRAM WAKE MORN EVE NIGHT 06:30A 08:30A 04:30P 10:30P MAIN MENU HEAT 70.0 62.0 70.0 62.0 COOL 78.0 85.0 78.0 82.0 The heating setpoint for the first event will be highlighted.
How do I copy one day’s program to another day? MONDAY PROGRAM MORN EVE NIGHT COPY 08:30A 04:30P 10:30P MAIN MENU HEAT 62.0 70.0 62.0 COOL 85.0 78.0 82.0 In the program screen, press the DOWN button until COPY is highlighted. SELECT COPY MONDAY TO TUESDAY WEDNESDAY THURSDAY FRIDAY FINISHED YES YES Use the UP or DOWN button to highlight the day to copy to. Press YES / NO. A YES will appear next to the day. Do this for each day to which that program is to be copied.
What are the USER settings? MONDAY 3:29 PM 78.1 COOL FAN AUTO HOLD TEMP MENU The USER SETTINGS can change the way information is displayed on the thermostat and help to optimize comfort. It’s one way to truly personalize your new thermostat. SET AT 78 MENU BACK HEAT / COOL DAY / TIME FAN USER SETTINGS are below the FAN settings. Use the DOWN button to scroll below the screen. Press SELECT. MORE USER SETTINGS HOME To get to the USER SETTINGS, press the MENU button from the main screen.
16 Detailed Information on the USER SETTINGS (Or what do these USER SETTINGS do?) To select a USER SETTING, use the UP or DOWN button to highlight the desired value. Press SELECT to select desired value. TEMPERATURE TEMPERATURE: Fahrenheit or Celsius Temperature will be displayed in F or C. ˚F ˚C USER MENU SELECT CLOCK CLOCK SETTINGS Displays time in standard 12-hour format or military format.
More Detailed Information on the USER SETTINGS. DIFFERENTIAL SETTING 1ST DIFF 2ND DIFF 2ND DELAY USER MENU 1˚F 2˚F 20 MIN SELECT SET COOLING LIMIT LOWEST COOLING SETTING ALLOWED USER MENU 45 °F SELECT SELECT A LANGUAGE DIFFERENTIAL SETTINGS The temperature differential is your comfort level. A lower differential means your system may cycle with greater frequency but will control closer to desired setpoint temperature.
18 More Detailed Information on the USER SETTINGS. SENSOR SETTINGS USE LOCAL SENSOR AVG. LOCAL / REMOTE USE REMOTE SENSOR USER MENU SELECT SECURITY CHANGE TEMP. ONLY PREVENT ALL CHANGES USER MENU SELECT ENTER SECURITY CODE FOR TEMPERATURE 0 0 0 0 USER MENU SELECT SENSOR SETTINGS This screen will appear when a remote indoor sensor (9020i) is connected to the thermostat. USE LOCAL SENSOR will disable the remote sensor and only sense from the thermostat. AVG.
What are the INSTALLER settings? The INSTALLER SETTINGS are setup during the initial installation. They tell the thermostat how to function with your heating or cooling equipment. The following is a brief overview and discussion of these settings.
20 INSTALLER settings (continued) AUXILIARY HEAT STANDARD - COMP. =ON ADD ON - COMP. =OFF INSTALL MENU SELECT AUXILIARY HEAT The 9720i can be set to use your 2H/2C heat pump internal auxiliary heating or to use an external add-on source. The add-on feature will be used most often when a single stage heat pump uses a gas or electric furnace as its second stage of heating.
INSTALLER settings (continued) ENERGY EFFICIENT RECOVERY DISABLE ENABLE USER MENU ENERGY EFFICIENT RECOVERY When turned on, the thermostat will look up to two hours before the next event and anticipate when to turn on to reach the desired temperature. SELECT DEADBAND SETPOINT 3 ˚F USER MENU DEADBAND SETPOINT Deadband is used with the AUTO CHANGEOVER feature. The deadband is the temperature difference from the setpoint temperature during which the heating or cooling will not be turned on.
22 CONTACT INFORMATION AIR EXPERTS 1-555-555-1212 BACK EDIT SERVICE MONITOR MENU SERVICE MONITOR FILTER MONITOR INSTALL MENU 980 980 SELECT REMINDER PERIOD RUN TIME CALENDAR TIME INSTALL MENU CONTACT INFORMATION This allows the servicing HVAC contractor to put their name and phone number into the thermostat to remind you when service may be required. SELECT SERVICE MONITOR MENU Two menus are available, the Service Monitor and the Filter Monitor.
26 When should I change the batteries? Only the model 9700i operates with batteries. The 9701i, 9715i and 9720i operate from power provided by your heating/cooling system. MONDAY 11:30 AM 70.0˚ F HOLD TEMP HEAT FAN AUTO SET AT 71.0˚F Generally the batteries will last 18-24 months. The thermostat will tell you when to change the batteries. A battery symbol will appear just below the temperature display.
28 515 South Promenade Avenue Corona, CA 92879-1736 United States of America Made in Mexico Patents Pending www.about-i-series.