Specification
3
SECTION 7: Handling and Storage
Precautions for Safe Handling: Obtain special instructions before use. Do not handle until all safety precautions have been read and
understood. Pressurized container: Do not pierce or burn, even after use. Do not use if spray button is
missing or defective. Do not spray on a naked flame or any other incandescent material. Do not smoke
while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose
containers to heat, flame, sparks, or other sources of ignition. All equipment used when handling the
product must be grounded. Do not re-use empty containers. Do not breathe gas. Avoid contact with
eyes, skin, and clothing. Avoid prolonged exposure. Use only in well-ventilated areas. Should be
handled in closed systems, if possible. Pregnant or breastfeeding women must not handle this product.
Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Avoid release
to the environment. Observe good industrial hygiene practices.
Conditions for Safe Storage: Level 2 Aerosol. Store locked up. Pressurized container. Protect from sunlight and do not expose to
temperatures exceeding 50°C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near
an open flame, heat or other sources of ignition. This material can accumulate static charge which may
cause spark and become an ignition source. Refrigeration recommended. Store away from incompatible
materials (see Section 10 of the SDS).
SECTION 8: Exposure Control / Personal Protection
OCCUPATIONAL EXPOSURE LIMITS
:
US OSHA
Specifically Regulated Substances
(29 CFR 1910.1001-1050)
Components
Type
Value
Dimethyl Ether (CAS 115-10-6)
STEL
TWA
2 ppm
075 ppm
US OSHA
Table Z-1 Limits for Air Contaminants
(29 CFR 1910.1000)
Components
Type
Value
Acetone (CAS 67-64-1)
PEL
2400 mg/m3
1000 ppm
n-Hexane (CAS 110-54-3
PEL
1800 mg/m3
500 ppm
Propane (CAS 74-98-6)
PEL
1800 mg/m3
1000 ppm
US ACGIH Threshold Limit Values
Components
Type
Value
2-Methylpentane (CAS 107-83-5)
STEL
1000 ppm
3-Methylpentane (CAS 96-14-0)
TWA
STEL
500 ppm
1000 ppm
Propane (CAS 74-98-6)
PEL
1800 mg/m3
1000 ppm
Acetone (CAS 67-64-1)
TWA
500 ppm
750 ppm
Dimethyl Ether (CAS 115-10-6)
STEL
CEILING
500 ppm
0.3 ppm
n-Hexane (CAS 110-54-3
PEL
50 ppm
US NIOSH: Pocket Guide to Chemical Hazards
Components
Type
Value
Acetone (CAS 67-64-1)
TWA
590 mg/m3
250 ppm
Dimethyl Ether (CAS 115-10-6)
CEILING
TWA
0.1 ppm
0.016 ppm
n-Hexane (CAS 110-54-3
PEL
180 mg/m3
50 ppm
Propane (CAS 74-98-6)
PEL
1800 mg/m3
1000 ppm