Service manual

SECTION 7: PUMP MOUNTING I NSTRUCTIONS
15 of 33
SECTION 7: PUMP MOUNTING INSTRUCTIONS
7.1 Mounting Platform
The standard method of mounting the pump is on an
outside wall and venting directly through the wall.
The pump may be mounted by using mounting
angles as shown in Figure 12 and Figure 13. The two
mounting angles form a mounting platform to which
the pump will be attached.
Fix the mounting frame to the wall using anchors.
Select an anchor that will give equal to or greater
than 2000 lbs ultimate pull-out strength.
FIGURE 12: Wall Bracket Assembly
FIGURE 13: Mounting Platform Options
Mounting
Angle
Hex Head Bolt
Flat Washer
Lockwasher
Hex Nut
Flat Washer
Description Part Number
Mounting Angle 01365000
Hex Bolt 5/16" x 3/4" 93413912
Flat Washer 95211600
Lockwasher 96411600
Hex Nut 92113900
10 5/8
(27 cm)
8 5/64
(20.5 cm)