- Roberts-Gordon The Economical, Unitary Infrared Heater Installation, Operation and Service Manual
ROBERTS GORDON
®
BH-SER I ES SUBMITTAL SHEET
© 2004 Roberts-Gordon
BEFORE IN STALLATION AND OPER ATION OF HEATING E QUIPMENT, READ AND U NDERSTAND THE INSTALLATION, OPERATIO N AND SERVICE MANUAL.
APPLICATION S, ENGI NEERING AND DETAILED GUID ANCE ON SYSTEMS DESIGN, INSTAL LATION AND PRODUCT PERFORMANCE IS AVAILABLE UPON RE QUEST. ROBERTS GORDON
®
PRODUCTS ARE TO BE
INSTALLED ONLY IN ACCORDANCE WI TH L OCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIE D IN THE INST ALLATION AND SE RVICE OF GAS-FIRED HEATING EQUI PME NT.
Electrical Connection to the Burner
Conduit Hole
BX or Romex Connector
Burner Box
Internal Wire Bundle
Green
White
Black
L1
L2
Gnd.
Connect Wires together with
suitable approved wire connections.
Green to Gnd.
White to L2
Black to L1
Electrical Cord or