Service manual
SECTION 5: PUMP I NSTALLATION
11
5.3 Wall Mounting
5.3.1 Wall Mounting Platform
The alternative method of mounting the pump is on
an outside wall and venting directly through the wall.
The optional mounting angle package
(P/N 01312102) must be ordered if this method is
used.
The pump may be mounted by using mounting
angles as shown in Figure 7 and Figure 8, Page 12 .
The two mounting angles form a mounting platform
to which the pump will be attached.
Fix the mounting frame to the wall using anchors.
Select an anchor that will give equal to or greater
than 2000 lbs ultimate pull-out strength.
FIGURE 7: Wall Bracket Assembly
WARNING
Suspension Hazard
Mount pump with materials
with a minimum working
load of 400 lbs (181 kg).
Failure of the supports can
result in death, injury
or property damage.
Mounting
Angle
Hex Head Bolt
Flat Washer
Lockwasher
Hex Nut
Flat Washer
Description Part Number
Mounting Angle Package 01312102
Mounting Angle 01365000
Hex Bolt 5/16" x 3/4" 93413912
Flat Washer 95211600
Lockwasher 96411600
Hex Nut 92113900