Service manual
SECTION 5: PUMP I NSTALLATION
9
5.1.5 Installing the Motor Shaft Seal
The motor shaft seal (P/N 02757500) eliminates air
leakage around the motor shaft and reduces the
associated noise. Install the shaft seal as follows:
1. Separate the motor shaft seal at the pre-cut
score line.
2. Wrap the shaft seal around the motor shaft hub
as shown.
3. Secure the shaft seal in position with the
adhesive strip provided.
FIGURE 5: Motor Shaft Seal Installation
WARNING
Electrical Shock Hazard
Disconnect electrical power before service or
maintenance.
Failure to follow these instructions can result in
death or electrical shock.
Motor Shaft Seal
EP-100 Motor
Pump Frame
Motor Shaft Hub
Impeller
Pump Inlet Assembly
Pump Scroll
Description Part Number
EP-100 Motor 90604600
Motor Shaft Seal 02757500
Pump Scroll 02757001
Impeller 02791601
Inlet Plate Assembly 02724200