SECTION 5: PUMP INSTALLATION
5.1 Pump Assembly Instructions
5.1.1 Determine Orientation of Pump Discharge
To ensure your safety and comply with the terms of
the warranty, all units must be installed in
accordance with these instructions.
The pump must be installed in a location that it is
readily accessible for servicing.
An arrow is affixed to the outside of the pump scroll to
indicate the direction of rotation of the impeller.
The standard rotation of the impeller is in the
counterclockwise direction.
Pump discharge orientation is viewed from the rear of
the motor as shown in on Page 6, Figure 2. Note that
the pump scroll outlet must always be positioned at
the bottom horizontal position.
FIGURE 2: Pump Discharge Orientation
5.1.2 Attaching Pump Scroll
After determining the correct orientation of the pump
scroll outlet, attach the pump scroll to the pump
frame using the #10 - 24 Keps locknuts provided.
NOTE: Periodically spin the impeller to be sure that
adequate clearance is maintained between the
impeller blades and the body of the pump scroll.
Arrow showing direction of rotation
(located on front of scroll housing)
Counterclockwise Rotation
(Standard)
OUTLET
Clockwise Rotation
OUTLET