Service manual
EP-100 PUMP INSTALLATION, OPERATION AND SERVICE MANUAL
8 of 29
FIGURE 3: Pump Discharge Orientation
5.1.2 Attaching Pump Scroll
After determining the correct orientation of the pump
scroll outlet, attach the pump scroll to the pump
frame using the #10 - 24 Keps locknuts provided.
NOTE: Periodically spin the impeller to be sure that
adequate clearance is maintained between the
impeller blades and the body of the pump scroll.
Arrow showing direction of rotation
(located on front of scroll housing)
Counterclockwise Rotation
(Standard)
OUTLET
Clockwise Rotation
OUTLET