Infrared Heating System Owner's Manual
ROBERTS GORDON
®
CRV-SERIES SUBMITTAL SHEET
© 2004 Roberts-Gordon
BEFORE INSTALLATIO N AND OPERATI ON OF HEATIN G EQUI PMENT, READ AND UNDERSTAND THE I NSTALLATION, O PERATION AND SERVICE MANUAL.
APPLICATIONS, ENGIN EERING AND DETAI LED GUIDANCE ON SYST EMS DESIGN, INSTALLATION AND PRODUCT PERFORMANCE IS AVAILABLE UPO N REQUEST. ROBERTS GORDON
®
PRODUCTS ARE TO BE
INSTALLED ONLY I N ACCOR DANCE WIT H LOCAL LAW S, CODES AND REGULATIONS, AND ONLY BY A CONTRACTO R QUALIFIED IN THE INST ALLATION AND SERVICE OF GAS-F IRE D HEAT ING EQUIPMEN T.
REFLECTOR INSTALLATION
Reflector Installation with Hole
Reflector Installation
Tube
Hanger
Combustion
Chamber
Slide Reflector
with hole
through hanger.
Unhook combustion
chamber from chain
and insert through hole.
Reconnect chain.
Reflector
with Hole
Description Part Number
Tube/Reflector Hanger 03090100
Tube 91409XXX
Reflector with Hole 02750304
Reflector
Wire Form
Tube
Reflector Support
Strap
Sheet Metal
Screw
U-Clip
(2 clips per
alternate overlaps
per side)
Description Part Number
Reflector Support Package 03050010
U-Clip Package 91107720
Reflector End Cap 027508XX