Home Security System User Manual

Table Of Contents
62 en | Configuring and Using the IP AutoDome VG4 AutoDome Modular Camera System
F.01U.089.433 | 4.0 | 2008.09 User’s Manual Bosch Security Systems, Inc.
To View a Preset Shot:
1. Click the number of the scene you want to view using the on-screen keypad.
2. Click the Show Shot button.
8.8 Alarm Connections
The Alarm Connections screen allows users to specify up to ten IP addresses which the device
attempts to establish a connection with in the event of an alarm. The device contacts the first
specified IP address and then each subsequent address until the device establishes a
connection.
Figure 8.16 Alarm Connections
To connect an alarm, do the following:
1. Open the IP AutoDome Livepage, then click the Settings tab.
2. Click the Alarm Settings link, then click Alarm Connections. The IP AutoDome displays
the Alarm Connections screen (see Figure 8.16).
3. Click the Connect on Alarm drop-down list and select On to establish a connection to a
pre-defined IP address in the event of an alarm. Off, indicates no alarm connections are
made and Follows Input x, triggers an alarm.
4. Click the Number of destination IP address drop-down list and select a number from one
to ten to specify the number of the IP addresses. To configure multiple IP addresses,
select a number for the destination IP address, configure the settings described below
and then click the Set button. You must click the Set button prior to configuring the
settings for another IP address.
5. Click inside the Destination IP address input box and type an IP address.
6. Click inside the Destination password input box and type the appropriate password for
the IP address, if required.
7. Click the Video transmission pull-down list and make a selection.
8. Click the Remote port pull-down list and make a selection. Depending on the network
configuration, select a browser port here. The ports for HTTPS connections will be
available only if the On option is selected for the SSL encryption parameter.
9. Click the Monitor pull-down list and make a selection from one to four.
10. Click the Coder pull-down list and make a selection from one to four.
i
NOTICE! For more information about the IP AutoDome settings and controls, click the Help on
this page? link to open the IP AutoDome online help.