Specifications

Installation and Manual Documentation
Document date:
CC-DA/ESR1
FR5CPCCF
08 Aug 2019
Page:
22
© All rights reserved, Robert Bosch GmbH, also for the case of protected rights applications every power of disposal, like copy-right
and passing on rights, with us. The valid issue of this template is filed in CC-DA process landscape.
3.2.2. Vehicle Power Supply
3.2.2.1. Constraints and Definitions
The car battery supplies power to the Sensor (terminal 15/30)
All power supply parameters are measured at the ECU vehicle connector supply pins (VBATT
to GND) unless different specified.
All power supply parameters are guaranteed and designed over ambient temperature Ta=
Ta_min to Ta_max unless different specified. (-40°C to 85°C, see Chapter "Operating
Environment")
All power supply parameters are guaranteed and designed over lifetime unless different
specified.
All power supply values are continuous values.
Definition COM Interfaces ON:
COM interfaces are working according to the respective communication standard.
3.2.2.2. Power Supply System 12V
Symbol Parameter Note or Test Condition min typ max Unit
Umin
min. voltage without
damageing the ECU
- reverse polarity
- t <= 60s
- Ri < 30mOhm
- 14,28 - 14,00 V
Symbol Parameter Note or Test Condition min typ max Unit
Umax_res_up
max. reset voltage Power
Up
- - 6,0 V
Symbol Parameter Note or Test Condition min typ max Unit
Umin_res_dn
min. reset voltage Power
Down
4,5 - - V
Symbol Parameter Note or Test Condition min typ max Unit
Umin_com min. communication voltage
- COM Interfaces ON
- Object list preservation
- min value Power Down
- max value Power Up
5,5 - 6 V