-14-
PROBLEM REMEDY
Red error indicator 4 flashes.
No charging procedure possible
The battery is not positioned (correctly)
Position the battery centrally with the battery base
on the charging platform
Detection of foreign object
An object other than / in addition to the
battery is on the charging platform
Remove object
Incorrect battery has been positioned on the
charging platform
Position compatible battery on the charging
platform
Battery pack defective Replace the battery
Standby indicator (green) does not illuminate
On board voltage too low Start engine (charge starter battery)
12V plug of the charger is not plugged in
(correctly)
Plug the 12V plug in the socket (completely)
Cable socket and cable connector not
(properly) connected
Connect cable socket and cable connector
Power supply is too warm Wait until the power supply has cooled
Defective cables, power supply or battery
charger
Check on board voltage, have power supply and
charger checked by an authorized Bosch service
center
Troubleshooting
2610041926 10-15 WC18CV_WC18C 10/7/15 9:07 AM Page 14