STEP 2 - PREP THE WALL
1. The mounting location for the cleats are determined by the pattern and the height of the mirror. Use the image below for the mounting
location for both of the cleats. The width measurements are the same for all sizes from the center line of the mirror.
2. Level and mark the holes that determine the location of both cleats.
3A. Locate the studs and drill four holes using a 3/32" drill bit.
3B. If no stud is available, drill a 1/4" hole for each wall anchor and use the supplied wall anchors*.
4. Use four screws provided to attach cleats to the wall.
5. Tighten screws until tight. When anchors are used, keep turning screw at least 4 more times as shown.
Inset and Column Light Pattern
Perimeter Light Pattern
8-3/8"
(213 mm)
8-3/8"
(213 mm)
8-3/8"
(213 mm)
4-3/16"
(106 mm)
4-3/16"(106 mm)
4-3/16"
(106 mm)
C
C
C
L
L
L
1-1/2"
(38 mm)
1-1/2"
(38 mm)
1-1/2"
(38 mm)
30" = 28-1/4" (718 mm)
40" = 38-1/4" (972 mm)
30" = 26-3/16" (665 mm)
40" = 36-3/16" (919 mm)
30" = 28-1/4" (718 mm)
40" = 38-1/4" (972 mm)
4X