Specification Sheet
Robern Inc N Wilson Ave Bristol PA
Installation
Electrical System
Profiles Modular Light x "
Page of
-rA
• Fixture adds 3-1/2" per light to the overall rough-in width when
ganged with Profiles cabinets and/or mirrors
• Rough Opening (light only) – 38-5/8" H x 2-3/4" W x 4" D
(981 mm H x 70 mm W x 102 mm D)
• Can be recessed or surface-mounted with 4" depth (D4) cabinets
(D4 surface-mount kit required) and fully recessed with 6" depth
(D6) cabinets
• Ganging kit required if used to mount with multiple cabinets -
light comes with ganging hardware on one side
Recessed Mount
Front View
*Lens dimensions are 1/8" (3 mm) smaller than light body
Surface Mount
Knockout
Location
2-3/4"
(70 mm)
Mounting block
preinstalled
15/16"
(24 mm)
3-1/2"*
(89 mm)
3-1/2"*
(89 mm)
3/4"
(19 mm)
39-3/8"*
(1000 mm)
Top View
Wall Wall
15/16"
(24 mm)
4"
(102 mm)
38-5/8"
(981 mm)
Rough
Opening
Height
4-11/16"
(119 mm)
3-3/4"
(95 mm)
20-7/8"
(530 mm)
18-1/2"
(470 mm)
• 120 VAC 60HZ 23W (46W for “V” Model)
• Class 2– Dimming Transformer
• Line voltage dimming with specified dimmer control
• (US) ETL and (Can) ETL Listed for Damp Locations
• Field wire location as shown in drawing
• Two 1/2" conduit (Ø 7/8" actual) electrical knockout locations shown
below
• Robern recommends the Maestro® C•L® Dimmers from LUTRON®,
Model # MACL-153M.
• “V” Model requires 2 dimmers and 3 wire + ground cable