STEP 6 - ELECTRICAL CONNECTION. DV MODELS
Refer to the Dimmer recommendations on page 2. Please note a 3-wire plus ground cable is required between xture and switch
box.
1. Determine the wire access hole center point by the height and width of the light (Fig. 1).
2. Pull eld wire through wire access hole on rear of the Light Case (Fig. 2).
3. Connect eld wire as shown (Fig. 3).
4. Once the connections are made, go to page 13 for Final Assembly.
120VAC
15A
3
Wire Access Hole Center Point
Rear of Light Fixture
2
1
*Make proper connections according to the
Dimmer’s Manufacturer Instructions. For on/off
(no dimmer) operation a standard wall switch
may be substituted in place of the dimmer.
Circuit Breaker
Dimmer*
= Field Connection
Light Case
White (N)
Ground (G)
Black (L)
White (N)
Black (L)
Ground (G)
30"
(762 mm)
40"
(1001 mm)
16-1/4"
(413 mm)
20-7/8"
(531 mm)
13-7/8"
(353 mm)
18-1/2"
(470 mm)
3-1/2"
(89 mm)
3-1/2"
(89 mm)
5"
(127 mm)
5"
(127 mm)
1-3/4"
(45 mm)
1-3/4"
(45 mm)
2-1/2"
(63.5 mm)
2-1/2"
(63.5 mm)
5600°K = LED’s with red and purple wire
2700°K = LED’s with red and gray wire
Black (L)
DC OUT
AC IN
to LED’s
to LED’s
DC OUT
AC IN
3 wire + ground eld wire
Red (L)
To other
light