Installation Guide
MPM / MTM Mirror and MPS Shelf System - Instructions
THE MPM / MTM SYSTEM OVERVIEW: WITH THE OPTIONAL MPS SHELF, THE SURFACE MOUNTED MIRROR PLUS MIRROR
SYSTEM CONSISTS OF FOUR ELEMENTS:
1. THE MP OR MT SERIES CABINET. 2. THE MPM OR MTM WALL MIRROR
3. THE MPS SHELF 4. THE MPSK OR MTSK SIDE KIT
IT IS IMPORTANT TO UNDERSTAND THAT THE MPS SHELF BRACKETS MUST BE INSTALLED ON THE CABINETS FIRST
BEFORE THE SIDE KITS. THE MPM WALL MIRROR IS HUNG ON ITS BRACKETS NEXT, THE SHELF IS INSTALLED IN ITS
BRACKETS LAST. THE RECESSED MPM SYSTEM CANNOT USE THE MPS SHELF. IF YOU ARE USING VERTICAL LIGHTS YOU WILL NEED
TO INSTALL THESE LIGHTS (WITH CABLE) BEHIND THE MIRROR. REFER TO THE M INSTRUCTION SHEETS FOR LIGHTS AND CABINETS
A. LAYOUT AND INSTALLATION OF THE MPM / MTM WALL MIRROR.
1. LOCATING THE CENTER OF THE ENTIRE CABINET / MIRROR COMBINATION.
CENTERLINE
BOTTOM OF
CABINET/MIRROR
24"
EXAMPLE:
TWO MP1640 WITH A MPM29.5AB
CENTER MIRROR IS 60" WIDE. LOCATE
THE VERTICAL CENTER LINE 30"
FROM THE LEFT OR RIGHT EDGE OR
CENTER THE LINE OVER THE FAUCET.
IN ADDITION, MARK A HORIZONTAL
LINE WITH A LEVEL AT THE DESIRED
BOTTOM POINT. WATCH FOR FAUCET
CLEARANCE WHEN USING THE MPS SHELF!
THE SHELF PROTRUDES 3/4" BELOW CAB.
PAGE 1
MIRROR WIDTH LESS 6"
USE
#10 X 2"
SCREWS
AND
WASHERS
WITH
ANCHORS
PROVIDED
2. PLACE THE TWO "Z" CLIPS ON THE WALL AS SHOWN.
NOTE 3:
THE MPM OR MTM
MIRROR IS THE
HEIGHT OF THE
CABINET, NOT THE
DOOR!
THE DOOR IS
APPROXIMATELY
1/8" SMALLER THAN
THE OVERALL
HEIGHT OF THE
CABINET.
THE MIRROR IS
DESIGNED TO
MATCH THE HEIGHT
OF THE SIDE KITS
AND CABINET.
C. SURFACE MOUNTED MP / MT CABINET LAYOUT AND INSTALLATION.
1.INSTALL THE MOUNTING ANGLE AS SHOWN ON PAGE 6 AND 7 OF YOUR CABINET INSTALLATION SHEET AND THE
DRAWING BELOW. PLEASE NOTE THAT THE MOUNTING ANGLE MUST BE CLEAR OF THE EDGE OF THE CABINET ON
THE MPM / MTM SIDE SO THAT THE MOUNTING ANGLE DOES NOT INTERFERE WITH THE SHELF BRACKET.
FOR THE MP16 OR MT16 CUT THE MOUNTING ANGLE TO 14"
FOR THE MP20 OR MT20 CUT THE MOUNTING ANGLE TO 18"
FOR THE MP24 OR MT24 CUT THE MOUNTING ANGLE TO 22"
2. INSTALL THE MPS SHELF BRACKETS ON THE CABINETS BEFORE THE CABINETS ARE INSTALLED. SEE SECTION D.
3. CONTINUE WITH THE ENTIRE CABINET, LIGHT AND SIDE KIT INSTALLATION. TEST FIT THE MIRROR. SEE SECTION E.
A. LAYOUT AND INSTALLATION OF THE MPM / MTM WALL MIRROR.
IMPORTANT
NOTE 1
CABINET
MOUNTING
ANGLE
CABINET
MOUNTING
ANGLE
BOTTOM OF MIRROR
AND CABINETS
M CAB.
WITH M-L1.5" SIDE LIGHTS
2 1/4"
M CAB.
WITH M-L1.5" SIDE LIGHTS
2 1/4"
M CAB. WITHOUT LIGHTS
3/4'
M CAB. WITHOUT LIGHTS
3/4'
BOTTOM OF
CABINET/MIRROR
ROUGH
OPENING
ROUGH
OPENING
3/8"
NOTE:
THIS DIMENSION IS
1/2 MIRROR WIDTH + 3/8"
EXAMPLE:
MPM29.5AB = 29 1/2" WIDE
ONE HALF WIDTH = 14 3/4"
14 3/4" + 3/8" = 15 1/8"
3/8"
3. TEST FIT THE MIRROR. ADJUST CLIPS IF NECESSARY. WITH A PENCIL, MARK THE LEFT AND RIGHT EDGES OF
THE MIRROR. REMOVE THE MIRROR WHILE INSTALLING THE CABINETS. BE CAREFUL NOT TO CHIP THE EDGES.
SECTION B DESCRIBES RECESSED MOUNTED CABINETS USED WITH THE MPM / MTM MIRROR.
SECTION C DESCRIBES SURFACE MOUNTED CABINETS USED WITH THE MPM / MTM MIRROR.
SECTION D DESCRIBES SURFACE MOUNTED CABINETS USED WITH THE MPS SHELF SYSTEM.
1. FOLLOW THE ROUGH OPENING GUIDE ON PAGE 1 OF THE MP OR MT CABINET INSTALLATION SHEET AND THE
DRAWING BELOW. BE SURE THE MPM / MTM MIRROR IS OFF THE WALL AND IN A SAFE PLACE BEFORE CUTTING
OPENINGS.
•IMPORTANT• DO NOT SECURE CABINETS TO THE WALL UNTIL YOU TEST FIT THE MPM MIRROR BETWEEN THE
CABINETS. SHIMMING MAY BE NECESSARY UNDER THE RECESSED PORTION OF THE CABINET.
B. RECESSED MOUNTED MP / MT CABINET LAYOUT AND INSTALLATION
M CAB.
WITH M-L3.5" SIDE LIGHTS
4 1/4"
M CAB.
WITH M-L3.5" SIDE LIGHTS
4 1/4"
IMPORTANT
NOTE 2 - PROPER
ANCHOR INSTALL