SDS

Baleco Int'l Inc Winter Clarifier Dated: 01/1/2016 Page 4 of 6
Skin corrosion/irritation Conclusion: No skin irritation
Serious eye damage/eye
irritation Conclusion: No eye irritation
Respiratory or skin sensitization Conclusion: Not sensitizing.
Germ cell mutagenicity
Genotoxicity in vitro AMES test: Remarks: No data available.
Carcinogenicity based on available data, the classification criteria are not met.
Reproductive toxicity
SECTION 12 ECOLOGICAL INFORMATION 12
Ecotoxicity effects
Aquatic Toxicity: Remarks: Ecotoxicological information is based on a structurally or compositionally
similar product.
LC50/96hr/Lepomis macrochirus (bluegill sunfish)/Acute toxicity/OECD Test Guideline 203: > 100 mg/l
Remarks: fresh water.
LC50/96/hr/Oncorhynchus mykiss (rainbow trout)/Acute toxicity/OECD Test Guideline 203: > 100 mg/l
Remarks: fresh water.
EC50/48hr/Daphnia magna (Water flea)/Immobilization/OECD Test Guideline 202: > 100 mg/l Remarks:
Ecotoxicological information is based on a structurally or compositionally similar product.
IC50/72hr/Green algae (Selenastrum capricornutum)/Growth inhibition/OECD Test Guideline 201: >100 mg/l
Remarks: Ecotoxicological information is based on a structurally or compositionally similar product.
Toxicity to other organisms: No data available.
Persistence and degradability
Biological degradability: Remarks: Ecotoxicological information is based on a structurally or
compositionally similar product.
CO
2
Evolution Test/OECD Test Guideline 301B/28 d: <70%
The polymeric ingredient is not readily biodegradable.
Bioaccumulative potential: Bioaccumulation is unlikely. Because of the high molecular weight of the
polymer diffusion through biological membranes is very small.
Partition coefficient: n-octanol/water: not applicable.
Other adverse effects: No data available. Additional ecological information: Ecotoxicological information is
based on a structurally or compositionally similar product. This material is not classified as dangerous to the
environment. The effects on aquatic organisms are due to an external (non-systemic) mode of action and
are significantly reduced (by a factor of 7-20) within 30 minutes due to the binding of the product to dissolved
organic carbon and inorganic sorbents such as clays or silts.
SECTION 13 DISPOSAL CONSIDERATIONS 13
Product: If recycling is not practical, dispose of in compliance with local
Regulations. Incineration is not recommended.
EPA Hazardous Waste NO.
Contaminated Packaging: Packages must be disposed of according to local and national regulations.
SECTION 14 TRANSPORT INFORMATION 14