Specifications

20
PAN/TILT feedback
This function allows to return the mowing head to the required position after changing the position by external
force (e.g.by stroke). Use the [Up] and [Down] keys to select "On" if you wish to anable this function or "Off"
if you wish not to return the mowing head to the required position and press [Enter] to confirm or [Mode] to
cancel and return to the menu.
Note: If the feedback was switched Off , the pan/tilt position is changed by external force and the feedbeck is
switched On again, the moving head might not to be synchronized with the DMX signal.You have to make a reset
in order to synchronize the moving head with the DMX signal.
Lamp Off via DMX
This function allows you to switch Off the lamp by DMX. Use the [Up] and [Down] keys to select "On" if you
want to switch Off the lamp by DMX or "Off" if you dont want to switch Off the lamp by DMX and press [Enter]
to confirm or [Mode] to cancel and return to the menu.
Temperature
Temperature readouts of the fixture inside in Celsius. Inside temperatures below 67° C are not critical. 67° C and
more lead to the lamp being switched off. Please note that the outside temperature should not exceed 40° C.
Low fan speed operating
By using this function you can choose 5 types of low fan speed operating. Browse through this menu by the
pressing [Up] and [Down] keys - the display shows step by step these messages: "AUTO, HIGH, reG, LoOF,
LoHI". Press [Enter] if you wish to select one of them or [Mode] to cancel and return to the menu.
high (max.) speed of fans
The cooling fans work on max. speed (max. cooling)
continuous controlling of the fan speed
The fan automatically raises its speed in order to control inside temperature of the lighting, if the
temperature inside increases about certain level (the low fan speed reduces the cooling of the
lighting). This cycle can repeat several times until the temperature inside is on suitable level.
low speed/Switch Off the lamp operating
The fan keeps the adjusted low speed until the temperature exceeds max. inside temperature of the
fixture, then the COLOR SPOT 575 automatically switch Off the lamp.