SCAN 575 XT Table of contents 1. Safety instructions ......................................................................................................... 4 2. Operating determinations ............................................................................................. 5 3. Description of the device .............................................................................................. 6 4. Installation .....................................................................................
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FORYOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
2. Operating determinations This device was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. When taking the device into operation, please make sure that the housing is closed firmly with all the necessary screws tightened up.
3.
4. Installation 4.1Fitting the lamp DANGER ! Install the lamps with the device switched off only. Unplug from mains before ! To insert the lamp (Osram HMI 575 W) open the cover by loosening the fastening screws at the sides of the cover. Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for. Damages caused by non-observance are not subject to warranty. Insert the lamp now.
4.3 Installation of an optional 12°lens The device is delivered with a 15°-standard lens. If you wish to insert an optional 12° lens (it is not standard part of delivery,only for request), please follow the instructions below: Remove the the 15°-objective by loosening the 3 fastening screws with an appropriate screwdriver. Fix the tube with the 3 screws and then screw the flange with 12°-lens . flange with 12°-lens tube 15°-objective 4.
The occupation of the connection-cables is as follows: Cable (EU) Cable (US) Pin International L Brown Black Live Light blue White Neutral Yellow/Green Green Earth N Do not connect the scanner to a dimmer system! 4.6 DMX-512 connection/connection between fixtures Master/slave operation Controller operation Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
5. DMX PROTOCOL Mode 1 Mode 2 Value 8bit channel channel channel 1 1 1 2 3 4 5 6 7 8 3 2 2 4 5 6 7 8 3 Function Type of control Pan 0-255 Coarse control of the pan movement proportional Tilt 0-255 Coarse control of the tilt movement proportional Pan fine 0-255 Fine control of the pan movement proportional Tilt fine 0-255 Fine control of the tilt movement proportional Speed of PAN/TILT movement 0 Max. speed 249 Min. speed 250-255 Max.
Mode 1 Mode 2 8bit Value channel channel channel 9 9 7 10 11 12 13 14 10 11 12 13 14 15 Frost,cor.
6.Controller mode The fixtures are individually addressed (001-497) on a data link and connected to the controller.The fixtures respond to the DMX signal from the controller. 6.1DMX addressing The control panel allows you to assign the DMX fixture address, which is defined as the first channel from which the SCAN 575 XT will respond to the controller. If you set, for example, the address to channel 5, the SCAN 575 XT will use the channel 5 to 20 for control.
Effect wheel This wheel has both hot and cold color temperature filters (3200 K and 5600 K). Total numbers of color combinations are 36. Also wash light and UV effect are provided by the special effect wheel. 3-facet rotating prism 3-facet prism rotating in both directions at different speed is situated at the special effect wheel. Focus Motorized focus enables the beam to be focused anywhere on stage.
7.Stand - alone mode The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture.To set the program to be played,see the "Stand-alone setting" ( menu "St.AL."). "Stand-alone operation" can be applied to the single fixture (the fixture may be set to the master /slave mode or controller mode ) or to multiple fixtures operating synchronously.
8. Functions of the control panel The control panel situated on the front side of the fixture offers several features. You can simply set the DMX address,master/slave mode, read the number of lamp or unit hours, switch On and Off the lamp, run test, make a reset and also use many functions for setting and service purposes. The main menu of the control panel is accessed by pressing the [Mode] button - press this one so many times until the display shows message "A001" (with actually stored address).
If message "MASt." fast flashes-DMX signal is received at the DMX-input- disconnect DMX controller! Only one fixture may be the master. Up to the 9 slaves may be connected to the master and on the certain address can be connected only one slave fixture (SLA1-SLA9).
- The number of the hours that the SCAN 575 XT has been powered On since the counter was last reset.Press [Enter] or [Mode] to return to the menu.In order to reset this counter to 0, you have to hold the [Up] and [Down]-button and press the [Enter]button. Lamp On time - This option enables you to read the total number of the operation hours with the lamp on since the SCAN 575 XT has been fabricated.Press [Enter] or [Mode] to return to the menu.
Software version By this function you can read the software version of the display module. Press [Enter] to read its value or [Mode] to return to the menu. 8.4 Personality options These options allow you to modify SCAN 575 XT operating behavior. Press [Up] and [Down] buttons to select the desired option and press [Enter] to set the value or to see next submenu. Pan reverse This function allows you to invert the pan movement.
10 Prism rotation control Prism rotation control 11 Rotating gobos Rotating gobos 12 Rot.gobo rotation Rot.gobo rotation 13 Iris Iris 14 Focus,Zoom Focus,Zoom 15 Shutter, strobe Shutter, strobe 16 Dimmer Dimmer 1 Please refer to the chapter "DMX- protocol" for detail description. Rot.
confirm or [Mode] to cancel and return to the menu.
temperature inside increases about certain level (the low fan speed reduces the cooling of the lighting). This cycle can repeat several times until the temperature inside is on suitable level.The initial level of the fan speed can´t be adjusted by the DMX. High (max.) speed of fans The cooling fan works on max. speed (max. cooling) Continuous controlling of the fan speed This mode is similar to "Auto", but the initial level of the fan speed can be adjusted by the DMX.
8.5 Switching On/Off the lamp Press the [Mode] button in order to access the main menu. Browse through the menu by pressing the [Up] and [Down] buttons until the display shows "LAMP". Confirm by pressing [Enter] button. Use the [Up] and [Down] buttons to select "On" to switch On the lamp and "Off" to switch Off the lamp and press [Enter] to confirm or [Mode] to cancel. 8.
Presetting playback This function allows you to select the the program which will be played in the stand-alone mode after switching the fixture On.Use the [Up] and [Down] buttons to select desired program ("tESt"- bilt-in program) or "OFF" if you don't want trigger any program after switching the fixture On and press [Enter] to confirm or [Mode] to cancel and return to the menu.Selected program will be played continuously in a loop as long as it appears on the display.
"dimr" "S.tim." "COPY." - a dimmer, value 0-255 a step time,value 0,1-25,5 seconds a copying the current prog. step to the next prog. step .If the last prog.step is copied to the next prog. step ,parameter "P.End" is increased about 1 by itself (except step 99). 5. Press Enter]-button to confirm adjusted value . 6. Press [Mode]-button,select next prog. step and repeat this procedure (steps 4 and 6). The editting programs "PrG.1,PrG.2,PrG.3" are saved in the current modified fixture (master or slave1-9).
Lamp adjustment This function can be used when you make the fine adjustment of the lamp.If you select "LAAd" pressing by [Enter]-button ,all effects will be canceled,shutter will be opened and the dimmer intensity will be set onto 100%.By using the options "PAn, tilt,Foc" you can focus the light on a flat surface (wall) and perform the fine lamp adjustment. Fixture code The option contains identification code (1-9999) for the fixture, which is used for the master/slave operation.
Now you can calibrate the the colour, gobo and effect wheels by your controller. The DMX calibration protocol is described in the table.
caused by the lamp. Caution: The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off. FAn The message informs you that the fixture was overheating and switched off. This message will appear on the display if the fan speed operating "LOOF" was selected. MbEr This messsage informs you that the main PCB does not communicate correctly with the Control Board.
10. Technical specifications Power supply: EU version -Voltage...........................208/230/240V AC, 50/60 Hz ~ -Fuse...............................T 5 A@ 230 V US version -Voltage...........................100/120/208/230 V AC, 50/60 Hz ~ -Fuse...............................T 10 A@120V -Power consumption..........
Beampath: Electronics: -Addressing, special functions setting, effects calibration via control panel with 4-digit LED display -Readout fixture and lamp usage, receiving DMX values, temperature, etc -Built-in analyzer for easy fault finding,error messages -Bilt-in demo sequences -Master-slave operation -Silent fan cooling, remotely controllable speed of fan -Self-resetable thermo-fuse -Digital serial input DMX-512 -DMX-control via every standard DMX controller -14 DMX-channels (8 bit Pan/Tilt movement resol
Housing - Easy access to lamp and main components thanks to large opening cover and the projector‘s modular construction. Dimensions (mm): Weight: 22 kg Accessories - Accessories gobo-set 6.......................15050015 Optional accessories: - Objective12° SCN.................................99010184 11. Maintenance and cleaning It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or within the fixture.
12. Appendix 12.1 Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency. The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed next to the power cord. If you want to change the power supply settings,follow the instructions: 1.Disconnect the fixture from AC power. 2.Remove the fixture cover by loosening the 4 screws. 3.