8
4.4 Replacing rotating gobos
Install gobos with the device switched off only.
Unplug from mains before!
To replace rotating gobos.
1. Disconnect the xture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently pull up the gobo holder from the rotation gobo wheel
.
4. Remove the spring gobo-lock with an appro
priate tool (e.g. small-bladed screwdriver) and remove it.
Do not touch the surface of the pattern of the glass gobo with bare ngers.
5. Remove the original gobo and insert the new one (glazy side towards the lamp). Insert the spring-gobo lock
to secure it in the gobo holder.
6. Insert the gobo holder back under the distance slots into rotating gobo wheel
.
5. Replace the bottom cover before applying power.