Specifications

30
6.2 Tab "Information"
Fixture Times - The menu provides readouts of xture operation hours.
Power On Time Hours - Select this menu to read the number of xture operation hours.
Total Hours -
The item shows the total number of the operation hours since the
Robin Cyclone
has been fabricated.
Resetable Hours -
The item shows the number of the operation hours that the
Robin Cyclone
has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Air Filters - Regular cleaning of the air lter on the side of the base is very important for the xture´s life
and performance.
Bild-up of dust, dirt and fog uid residues reduces the cooling of the base inside.
The two items of this menu help you to keep cleaning period of the air lter.
Alert period - Cleaning schedule for the xture depends on the operating environment.
It is therefore impossible to specify accurate cleaning interval. This item allows
you to change the cleaning interval of the air lter. This "alert" value is 300 hours and it
is set as default. Inspect the xture within its 300 hours of operation to see whether cleaning
is necessary. If cleaning is required, clean air lter and change the value in this menu
on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time - The item allows you to read the time which remains to cleaning air lter.
The time period is set in the menu mentioned above.
Expired time period is signalled by a negative mark (-) at the time value and a warning icon
on the display.
Clean the lters and reset this menu item (by touching the text box next to the item
"Elapsed Time").
Fixture Temperatures - The menu is used to view temperatures of the xture´s inside.
LEDs Temperature - The menu shows temperatures in the LED module.
Current - A current temperature of the LED module.
Maximum NonRes. - A maximum temperature of the the LED module since the xture has
been fabricated.
Maximum Res. - A maximum temperature of the the LED module since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Ambient Temperature - The menu shows temperature of the induced air on the fan in the xture base .
Current - A current temperature of the induced air in the xture base.
Maximum NonRes. - A maximum temperature of the induced air in the xture base since
the xture has been fabricated.
Maximum Res. - A maximum temperature of the induced air in the xture base since
since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Base Temperature - The menu shows temperature in the xture base.
Current - A current temperature in the xture base.
Maximum NonRes. - A maximum temperature in the xture base since the xture has
been fabricated.
Maximum Res. - A maximum temperature in the xture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
DMX Values - The menu is used to read DMX values of each channel received by the xture.
Wireless State - The menu serves for reading of the wireless operation status (only for Wireless DMX ver-
sion).
Unlink Wireless Adapter - The item serves for unlinking the xture from the transmitter.
Product IDs - The menu is used to read the MAC Address ,RDM UID and RDM Label.
Software Version - Select this item to read the software version of the xture modules: