Specifications

27
this window and the xture will reset with the new software.
Note: In the case of an interruption of the upload process (e.g. power cut), the xture keeps the updating mode
and you have to repeat the software update again.
7.7 Icon "Lamp menu"
Lamp Status - The item enables to switch the lamp on/off. The MSR Gold 575/2 MiniFastFit lamp is a cold
restrike type, that means, that it has to be cold before striking.
Settings - The menu offers many items for setting of lamp behaviour.
Lamp Ignition Delay - The item allows to set the time delay( 0-90sec.) before igniting the lamp by DMX
command. If the lamp is started directly from the control panel, the time delay will be ignored.
Lamp Light Sensor - Select this item to switch the light sensor off. The option "On” is intended for a standard
operation. The option "Off” is for “emergency operation” only! If the lamp light sensor is switched off, the xture
will still try to ignite the lamp (even when the lamp is damaged or absent), on this account some electronics
parts of the xture can be damaged!
Lamp On/Off Settings - Use the menu to set rules for automatic switching on/off the lamp.
Lamp On Power On - If the item is on, the lamp will be automatically turn on after switching the
xture on.
Lamp Off via DMX - The item enables to switch the lamp off via DMX command from DMX
controller.
Lamp On if DMX Present - The item allows you to strike the lamp automatically after 26 seconds
if DMX signal is present on the xture´s DMX input.
Lamp Off if not DMX - The item allows you to switch off the lamp automatically after 2 minutes
if DMX signal is missing on the xture´s DMX input.
8. RDM
This xture supports RDM operation. RDM (Remote Device Management) is a bi-directional communications
protocol for use in DMX512 control systems, it is the new open standard for DMX512 device conguration and
status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting
existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specications
for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive
messages from specic moving lights.
RDM allows explicit commands to be sent to a device and responses to be received from it.
The list of commands for Robin 600E Beam is the following.
Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *
DISC_MUTE *
DISC_UN_MUTE *
DEVICE_INFO *
SUPPORTED_PARAMETERS *
SOFTWARE_VERSION_LABEL *
DMX_START_ADDRESS * *
IDENTIFY_DEVICE * *
DEVICE_MODEL_DESCRIPTION *
MANUFACTURER_LABEL *
DEVICE_LABEL * *
SENSOR_DEFINITION *
SENSOR_VALUE *
DISPLAY_INVERT * *
DISPLAY_LEVEL * *
PAN_INVERT * *