Specifications

6
3. Installation
Fixtures must be installed by a Qualied electrician in accordance with all
national and local electrical and construction codes and regulation.
3.1 Connection to the mains
For protection from electric shock, the xture must be earthed!
The Robin 100 LEDBeam is equipped with auto-switching power supply that automatically adjusts to any 50-
60Hz AC power source from 100-240 Volts.
If you need to install a suitable plug on the power cord, note that the cores in the power cord are coloured ac-
cording to the following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualied electrician.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
This device falls under class one and must be earthed (grounded)!
Design of the Robin 100 LEDBeam allows to connect several xtures to AC mains power in one interconnected
daisy chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specications “
The max. number of connected xtures depends on the AC mains power voltage:
12 xtures at power supply= 230V
10 xtures at power supply= 208V
6 xtures at power supply= 120V
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by qualied staff!