Specifications

REDMix3•192
7
Theshape(dimensions)oftheplasticfilmdependsonitsthicknessandelasticity.Weadvicetouse2shapesof
plasticfilms:
Thickness=<0.5mmThickness>0.5mm

Maximumthicknessofthefilmshouldnotexceed0.8mm.
3.3Connectiontothemains
Ifitisnecessary,installasuitableplugonthepowercord,notethatthecoresinthepowercablearecolored
accordingtothefollowingtable.
Core(Eu) Core(US) Connection PlugTerminalMarking
Brown Black Live L
Lightblue White Neutral N
Yellow/Green Green Earth

Thisdevicefallsunderclassoneandmustbeearthed(grounded)!
TheREDMix3•192allowstoconnectseveralfixturesinadaisychainofpowercable.Usea3conductor1.5mm
2
patchcordforconnectingfixtures eachother.Neededtypesofthecableconnectorsarestatedinthechapter
“Technicalspecificationsundersection.
Themax.numberofconnectedfixturesdependsontheinputvoltage:
4fixturesatpowersupply=230V(“FuLL”powermode)
2fixturesatpowersupply=120V
(“FuLL”powermode)
Donotoverloadthesupplylineandtheconnectingleads.
Wiringandconnectionworkmustbecarriedoutbyqualifiedstaff!