Specifications
REDMix3•192
19
6.5Testsequences
Usethismenutorundemo‐testsequenceswithoutanexternalcontroller,whichwillshowyousomepossibilities
ofusingtheREDMix3•192.
6.6Standalonesetting
Thefixturesonadatalinkarenotconnectedtothecontrollerbutcanexecutepre‐setprogramswhichcanbe
differentforeveryfixture.“Stand‐aloneoperation”canbeappliedtothesinglefixtureortomultiplefixtures
operatingsynchronously.
Synchronousoperationofmultiplefixturesrequiresthattheymust
beconnectedonadatalinkandoneofthemis
setasamaster(“MASt“)andtherestastheslaves(“SLA“).Upto32fixturescanbeconnectedinamaster/slave
chain.Onlyonefixturecanbesetasthemaster.
Note:DisconnectthefixturesfromtheDMXcontroller
beforemaster/slaveoperating,otherwisedatacollisionscan
occurandthefixtureswillnotworkproperly.Seethechapters“Stand‐aloneoperation“and“Master/slave
connection“.
Auto.
‐‐‐Automaticplayback.Thisfunctionallowsyoutoselecttheprogramwhichwillbeplayedafterswitching
thefixtureon.Selectedprogramwillbeplayedcontinuouslyina loop.
1. UsetheUP/DOWNbuttonstofind“St.AL.“menu.
2. PresstheENTERbutton.
3. UsetheUP/DOWNbuttonsto
select“Auto“item.
4. PresstheENTERbutton.
5. UsetheUP/DOWNbuttonstoselectdesiredprogram.
6. PresstheENTERbuttontoconfirmthechoice.
PLAY
‐‐‐Playingprogram.Byentertothismenuacompleteoverviewofallprogramsisoffered,fromwhichthe
programtoberuncanbeselected.
1. UsetheUP/DOWNbuttonstofind“St.AL.“menu.
2. PresstheENTERbutton.
3. UsetheUP/DOWNbuttonstoselectdesiredprogram.
4. PresstheENTERbutton. Theselectedprogramrunsinaloop.
Edit
‐‐‐Editingaprogram. Thefixtureoffers3freelyeditableprograms(EPG.1‐EPG.3)eachupto68steps.Every
programstepincludesafadetime
‐thetimetakenbythestep´schannelstatustoreachthedesiredlevelanda
steptime
‐thetotaltimeoccupiedbythestepintheprogram.
E.g.If“F.tim.“=5secondand“S.tim.“=20second,effectswillgotothedesiredpositionduring5secondsandafter
thattheywillstayinthispositionfor15secondsbeforegoingtothenextprog.step
1. 1.Usethe
UP/DOWNbuttonstofind“St.AL.“menuandpresstheENTERbutton.
2. UsetheUP/DOWNbuttonstoselect“Edit“menuandpresstheENTERbutton.
3. UsetheUP/DOWNbuttonstoselectaprogramyouwanttoedit(PrG.1‐PrG.3andpressENTERbutton.
4. UsetheUP/DOWNbuttons
toselectadesiredprogramstep("St.01"‐"St.68")andpressENTERbutton.
5. UsetheUP/DOWNbuttonstoselectachannelyouwanttoeditandpresstheENTERbutton.
Listofeditableitems:
“P.End”‐atotalnumberoftheprogramsteps(value1‐68).Thisvalueshould beset
beforestart
Programming(e.g.ifyouwanttocreateprogramwith10steps,setP.End=10).
“rEd1”‐“rEd4”–aredLEDssaturation(0‐255)
“GrE1“‐“GrE4“–agreenLEDssaturation(0‐255 )
“bLu1“‐“bLu4“–ablueLEDssaturation(0‐255)
“Whi1“‐“Whi4“–awhiteLEDssaturation(0
‐255)