version 1.
REDBlinder 2•48 Table of contents 1. Safety instructions.......................................................................................................... 4 2. Operating determinations............................................................................................... 4 3.Description of the REDBlinder 2•48................................................................................ 5 4.Installation....................................................................................
CAUTION! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this product has to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
3.Description of the REDBlinder 2•48 1 1 - Mounting yoke 2 - "T" bar 3 - LED modules 2 3 Control board 1 - 5-pin DMX output 2 - 3-pin DMX output 3 - 5-pin DMX input 4 - 3-pin DMX input 5 - LED display 6 - Mode-button 7 - Enter-button 8 - Up-button 9 - Down-button 10 - Fuse holder 11 - Mains input 4.Installation 4.1.Connection to the mains The REDBlinder 2•48 is equipped with auto-switching power supply that automatically adjusts to any 50/60 Hz AC power source from 100-240 volts.
4.2 DMX-512 connection/connection between fixtures The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate cord .Fasten the safety cord through the mounting yoke and over the trussing system. When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, under high working places and other endangered areas is forbidden.
5.REDBlinder 2•48 - DMX protocol ,version 1.
8 5 9 6 0-31 32-63 64-95 96-127 128-143 144-159 160-191 192-223 224-255 0-255 SHUTTER/STROBE Shutter closed Shutter open Strobe-effect from slow to fast Shutter open Opening pulses in sequences from slow to fast Closing pulses in sequences from fast to slow Shutter open Random strobe-effects from slow to fast Shutter open step step proportional step proportional proportional step proportional step DIMMER Dimmer intensity from 0% to 100% proportional Zone positions: (every zone contains tw
6.REDBlinder 2•48 - Control menu map Default settings=Bold print A001 (001-504) ProG EPG.1 EPG.2 EPG.3 PrG.1 : PrG.6 Auto (OFF,On) Edit. EPG.1 EPG.2 EPG.3 St.01 : St.30 P.End rEd (0-255) : dimr. (0-255) F.tim.(0-255) S.tim. (0-255) COPY. MAn.C. rEd (0-255) GrEE. (0-255) bLuE (0-255) : MACr (0-255) Stro. (0-255) dimr. (0-255) tESt St.AL. MASt.
7.Control board The control panel situated on the top cover of the REDBlinder 2•48 allows DMX addressing,calling build-in programs and setting the fixture behaviour. Control elements on the control board: [MODE] button-leaves menu without saving changes. [ENTER] button- enters menu,confirms adjusted values and leaves menu. [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
Following item are common for all zones: MACr. - a macro selection,value 0-255 Stro. - a strobe,value 0-255 dimr. - a dimmer,value 0-255 F.tim. - fade time,value 0-255 * S.tim. - standing time,value 0-255 * COP. - copying the current prog. step to the next prog. step. Press [ENTER]-button to confirm adjusted value . 5.Repeat steps 3 and 4 for next prog.step.If you want to copy current prog. step to the next prog.step, select option "COPY."and confirm it by pressing [ENTER].
7.5 Stand-alone mode Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master ("MASt.") and the rest as the slaves ("SLA.").Only one fixture can be set as the master.The slaves mimic the behavior of the master.Effect actions are triggered by an internal timer of the master fixture.
1.DMX Software Uploader program is available from the ROBE web site at WWW.robe.cz. 2.Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it. 3.Unpack the program from the archive. Program file has name:DSU_name of corresponding fixture_SoftwareID.SoftwareID describes the versions of fixture software included in DMX Software Uploader. Higher number means later software versions. 2.Fixture software updating: 1.
Technical Specifications Power supply: Input Voltage:100-240V AC, 50/60 Hz Fuse:T 2 A Max.
Optional Accessories Set glass frost (No.99011539).................4 pieces Set film frost (No.99011540)....................4 pieces 9.Maintenance Keep the Led Blinder 248 LT dry. Operate only in places where the sufficient airflow to cool the fixture is present Periodically clean the front transparent cover of LED modules Use a moist, lint-free cloth. Never use alcohol or solvents! In order to maintain adequate cooling,dust must be cleaned from the air vents. Replacing the fuse 1.