version 1.
Led Blinder 196 LT Table of contents 1. Safety instructions ......................................................................................................... 4 2. Operating determinations.............................................................................................. 4 3.Description of the LedBlinder 196 LT............................................................................ 5 4.Installation........................................................................................
CAUTION! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this product has to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
3.Description of the LedBlinder 196 LT 1 1 - Mounting yoke 2 - "T" bar 3 - LED modules 2 3 Control board 1 - 5-pin DMX output 2 - 3-pin DMX output 3 - 5-pin DMX input 4 - 3-pin DMX input 5 - LED display 6 - Mode-button 7 - Enter-button 8 - Up-button 9 - Down-button 10 - Fuse holder 11 - Mains input 4.Installation 4.1.Connection to the mains The LedBlinder 196 is equipped with auto-switching power supply that automatically adjusts to any 50/60 Hz AC power source from 100-240 volts.
4.2 DMX-512 connection/connection between fixtures The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
The fixture should be hung on a truss structure using a mounting clamp (not included).Mounting yoke has a 13 mm diamer hole for fixing the mounting clamp.The fixture can be tilted + - 180°.The required tilt angle of the fixture can be adjusted by means of the "T" bar on the side of the fixture. The installation must always be secured with a secondary safety attachment, e.g. an appropriate cord .Fasten the safety cord through the mounting yoke and over the trussing system.
5.Led Blinder 196 LT-DMX protocol ,version 1.
13 4 14 5 15 6 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro 21 Macro 22 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Macro 31-rainbow effect from slow to fast step step step step step step step step step step step step step step step proportional 0-31 32-63 64-95 96-127 128-143 144-159 160-191 192-223 224-255 SHUTTER/STROBE Shutter closed
6.Led Blinder 196 LT- Control menu map Default settings=Bold print A001 (001-498) ProG EPG.1 EPG.2 EPG.3 PrG.1 : PrG.6 Auto (OFF,On) Edit. EPG.1 EPG.2 EPG.3 St.01 : St.30 MAn.C. rEd (0-255) GrEE. (0-255) bLuE (0-255) : MACr (0-255) Stro. (0-255) dimr. (0-255) tESt St.AL. MASt. SLA. EPG.1 : PrG.6 SPEC. VErS. bALA. (On,OFF) C.bAL. rEd.b. (0..200..255) GrE.b.(0..255) bLu.b. (0..215..255) dM.Pr. Mod.1 Mod.2 Mod.3 Mod.4 i.bLi (On,Off UPd.(no,YES) 10 P.End rEd 1 (0-255) : dimr. (0-255) F.tim.(0-255) S.
7.Control board The control panel situated on the top cover of the LedBlinder 196 allows DMX addressing,calling build-in programs and setting the fixture behaviour. Control elements on the control board: [MODE] button-leaves menu without saving changes. [ENTER] button- enters menu,confirms adjusted values and leaves menu. [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
rEd.3 - a red LEDs 3 saturation,value 0-255 GrE.3 - a green LEDs 3 saturation,value 0-255 bLu.3 - a blue LEDs 3 saturation,value 0-255 rEd.4 - a red LEDs 4 saturation,value 0-255 GrE.4 - a green LEDs 4 saturation,value 0-255 bLu.4 - a blue LEDs 4 saturation,value 0-255 Following item are common for all zones: MACr. - a macro selection,value 0-255 Stro. - a strobe,value 0-255 dimr. - a dimmer,value 0-255 F.tim. - fade time,value 0-255 * S.tim. - standing time,value 0-255 * COP. - copying the current prog.
7.4 Test sequences Use the item to run a special demo-test sequences without an external controller,which will show you some possibilities of using the fixture. 7.5 Stand-alone mode Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master ("MASt.") and the rest as the slaves ("SLA.").Only one fixture can be set as the master.The slaves mimic the behavior of the master.
Note1:Software update should execute a qualified person.If you lack qualification, do not attempt the update yourself and ask for help your ROBE distributor. Note 2:DMX address,programs and all settings will be set to their default values To update software in the fixture: 1.Installation of DMX Software Uploader: 1.DMX Software Uploader program is available from the ROBE web site at WWW.robe.cz. 2.Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it. 3.
Led Blinder 196 - Technical Specifications Power supply: Input Voltage:100-240V AC, 50/60 Hz Fuse:T 3.15A Max.
Optional Accessories Set glass frost (No.99011539) Set film frost (No.99011540) Cover for LED Blinder 196 (No.10980037) 9.Maintenance Keep the Led Blinder 196 dry. Operate only in places where the sufficient airflow to cool the fixture is present Periodically clean the front transparent cover of LED modules Use a moist, lint-free cloth. Never use alcohol or solvents! In order to maintain adequate cooling,dust must be cleaned from the air vents. Replacing the fuse 1.