Specifications

31
next prog. step ,parameter "P.End" is increased about 1 automatically (except step 99).
5. Press Enter]-button to confirm adjusted value .
6. Press [Mode]-button,select next prog. step and repeat this procedure (steps 4 and 6).
The editting programs "PrG.1,PrG.2,PrG.3" are saved in the current modified fixture (master or slave1-9).
8.8.Reset function
Press [Enter] button to run a reset. This option enables the IMAGE SPOT 250 AT to index all effects (functions)
and return to their standard positions.
8.9.Special functions
Use the [Up] and [Down] buttons to browse through the special functions and select the one by pressing [Enter].
- Manual control of effects
The function allows you to control manually the channel functions of the fixture. Use the [Up] and [Down]
buttons to select desired function and press [Enter] to adjust the effect or [Mode] to cancel and return to the
menu.
- Lamp adjustment
This function can be used when you make the fine adjustment of the lamp.If you select "LAAd" pressing by
[Enter]-button ,all effects will be canceled,shutter will be opened and the dimmer intensity will be set onto 100%.By
using the options "PAn, tilt,Foc" you can focus the light on a flat surface (wall) and perform the fine lamp
adjustment.