Specifications

21
2. Press [Enter]-button and use the [Up] and [down] buttons to select "MA.SL."-menu.
3. Press[Enter]-button(display flashes) and select"MASt."(to set the fixture as the master in a chain of multiple
fixtures) or "SLA.1"-"SLA.9" (to set the fixture to be the slave in a chain of multiple fixtures) and press [Enter]
to confirm. If you want address no master or slave, select "d.AbL.".
4. Press the [Mode]- button.Choosen address is shown on the display.
If message "MASt." fast flashes-DMX signal is received at the DMX-input- disconnect DMX controller!
Only one fixture may be the master. Up to the 9 slaves may be connected to the master and on the certain
address can be connected only one slave fixture (SLA.1-SLA.9).
Note:Disconect the fixtures from the DMX controller before master/slave operating ,otherwise data collisions can
occur and the fixtures will not work properly!
If the fixture is set as the master and DMX signal is connected to its input,the error massage "MA.Er." will appear
on its display and the fixture address will be set to its DMX address in order to respond to DMX signal from the
controller.
For example:
The master fixture has this address setting:"dM.Ad."-menu.........A011
"MA.SL."-menu........MASt. (is displayed)
The DMX signal is connected to the master fixture.The message "MAst." starts fast flashing and after 20s error
massage "MA.Er." appears on its display and the fixture automatically will be switched to its DMX address
(master address is disabled).
Now the fixture has the address setting: "dM.Ad."-menu.........A011 ("A011"/ MA.Er."blinks )
"MA.SL."-menu.........d.AbL.
If the fixture is set as the slave and DMX signal is connected to its input,the fixture will respond to DMX signal
from the controller (in dependence on the fixture's DMX address).
8.2.Slave control
This function allows you to control the slaves from the master's control panel in a master/slave operation.
Select this function from the main menu and press [Enter]-button.Browse the list of all connected slaves ("SL.C.1"
- "SL.C.9") by pressing [Up] or [Down] button.Select the desired slave and press [Enter]-button.The slave's
control panel is available from the master's control panel.
If no slave is connected to the master,massages "SL.C.1","SL.C.2","SL.C3"..."SL.C.9" still round repeat.
Note:This function is available from the master fixture only.
8.3.Fixture informations
The menu allows you to read an useful information about the fixture as the lamp life,head temperature,software
version, etc.
Press [Up] and [Down] buttons to select the desired option and press [Enter] to see the value or next submenu.