IMAGE SPOT 250 AT Table of contents 1. Introduction .................................................................................................................... 3 1.1.Description of the device ............................................................................................ 4 2.Safety ............................................................................................................................... 6 2.1.Safety instructions .....................................................
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Introduction Thank you for having chosen a IMAGE SPOT 250 AT. You acquired a versatile, powerful and intelligent lightingeffect. Unpack your IMAGE SPOT 250 AT and make sure that there are no damages caused by transportation.
1.1.
Infra-red remote control 21 - Red LED 22 - Up-button 23 - Down-button 24 - Infra-red transmitter 25 - Lamp on-button 26 - Mode-button 27 - Blackout/lamp off-button 28 - Enter-button 5
2.Safety 2.1.Safety instructions Caution ! Be careful with your operations.With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual. Important: Damages caused by the disregard of this user manual are not subject to warranty.
fixture at the transport handles. When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust. There should not be any cables lying around. You endanger your own and the safety of others! The minimum distance between light-output and the illuminated surface must be more than 1,3 meter. Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
Fastening screws Fastening screws Top cover Lamp cover Lamp To insert the lamp MSD 250W/2 open the top cover of the projector-head (see the drawing to identify which cover is top) by loosening the 3 screws on the cover. Then open the small lamp cover by loosening 2 fastening screws (see the drawing). If changing the lamp, remove the old lamp from the socket. Insert the lamp to the socket. Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for.
The lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve light performance. Strike the lamp, cancel all effects, open the shutter and dimmer , focus the light on a flat surface (wall) or use function "LAAd" in the Special functions .
3.3.Rigging DANGER TO LIFE! Please consider the respective national norms during the installation! The installation must only be carried out by an authorized dealer! The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
The fixture can be placed directly on the stage floor or rigged in any orientation on a truss without altering its operation characteristics (see the drawing). There are two possibility how to fix the IMAGE SPOT 250 AT on a truss: with the clamp brackets or mounting plate (see the drawings below).Use the rigging clamps with screws M12. For overhead use, always install a safety-rope that can hold at least 10 times the weight of the fixture. You must only use safety-ropes with screw-on carabines.
Fixation via a mounting plate (mounting plate is not standard part of the fixture) The fixture's base enables to be mounted in two ways using the special mounting plate : 1. Screw the 2 clamps to the included mounting plate with M12 bolts and nuts through the holes in the mounting plate. 2. Insert the 4 quick-lock fasteners into the holes on the bottom of the base and tighten fully clockwise. 3. Fasten the safety-rope through the two apertures on the bottom of the base and over the trussing system.
3.4.Connection to the mains Connect the fixture to the mains with the enclosed power-plug. The earth has to be connected! The occupation of the connection-cables is as follows: Cable (EU) Cable (US) Pin International Brown Black Live L Light blue White Neutral N Yellow/Green Green Earth 3.5.Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
US-version power supply settings: 120V/60Hz 3.6.DMX- 512 connection, master/slave connection Controller operation Master/slave operation Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
Building a master/slave-chain: Connect the DMX-output of the master fixture in the data-chain with the DMX-input of the first slave. Always connect output with the input of the next slave until all slaves are connected (up to 9 fixtures). Caution:It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link.
4.DMX Protocol Channel Channel 16 bit 8 bit 1 Value 1 Pan Pan movement by 530° proportional 0-255 Pan fine Fine control of pan movement proportional 0-255 Tilt Tilt movement by 280° proportional 0-255 Tilt fine Fine control of tilt movement proportional 2 4 5 3 0 1-249 250-252 253-255 6 7 8 9 4 Speed of PAN/TILT movement Max. speed (tracking mode) From max. speed to min.speed (vector mode) Max. speed,(tracking mode) Max.
5.Control The IMAGE SPOT 250 AT is controled by the 4-buttons control panel on the front side of the base or by the 6buttons infra-red remote controller. Control panel: Two LEDs on the control panel display the fixture status. Red LED indicates normal operation after switching the fixture on.Green LED indicates the lamp is switched on. Green LED Red LED Remote control: The red LED on the remote control indicates if any button is pressed (the signal is transmited).
6.1.DMX addressing The control panel on the front side of the base allows you to assign the DMX fixture address, which is defined as the first channel from which the IMAGE SPOT 250 AT will respond to the controller. If you set, for example, the address to channel 5, the IMAGE SPOT 250 AT will use the channel from 5 to 14 for control. Please, be sure that you don’t have any overlapping channels in order to control each IMAGE SPOT 250 AT correctly and independently from any other fixture on the DMX data link.
"Stand-alone operation" can be applied to the single fixture (the fixture may be set to the master /slave mode or controller mode ) or to multiple fixtures operating synchronously. Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master (master mode) and the rest as the slaves (slave mode).The slaves are assigned to SLA1-SLA9 and on the certain slave address can be connected only one fixture.
The played program is the same for all time(light level) periods. From the master's control panel is possible to control any slave in a master/slave chain.
2. Press [Enter]-button and use the [Up] and [down] buttons to select "MA.SL."-menu. 3. Press[Enter]-button(display flashes) and select"MASt."(to set the fixture as the master in a chain of multiple fixtures) or "SLA.1"-"SLA.9" (to set the fixture to be the slave in a chain of multiple fixtures) and press [Enter] to confirm. If you want address no master or slave, select "d.AbL.". 4. Press the [Mode]- button.Choosen address is shown on the display. If message "MASt.
- Power On time - By this option you can read the total number of the operation hours since the IMAGE SPOT 250 AT has been fabricated. Press [Enter] or [Mode] to return to the menu. - The number of the hours that the IMAGE SPOT 250 AT has been powered On since the counter was last reset.Press [Enter] or [Mode] to return to the menu.In order to reset this counter to 0, you have to hold the [Up] and [Down]-button and press the [Enter]-button.
- Software version By this function you can read the software versions of the display module. Press [Enter] to read its value or [Mode] to return to the menu. 8.4.Personality options These options allow you to modify IMAGE SPOT 250 AT operating behavior. Press [Up] and [Down] buttons to select the desired option and press [Enter] to set the value or to see next submenu. - Pan reverse This function allows you to invert the pan movement.
- Lamp On after switching the fixture On This function enables to turn the lamp on automatically after switching the fixture on. Use the [Up] and [Down] buttons to select "On" if you wish to turn the lamp on automatically after switching the fixture on or "Off" if you wish the lamp off after switching on the fixture and press [Enter] to confirm or [Mode] to cancel and return to the menu. - Lamp Off via DMX This function allows you to switch off the lamp by DMX.
- Display intensity With this function you can adjust the display-intensity from 20% to 100% . Use the [Up] and [Down] buttons to select the level of the display- intensity and press [Enter] to confirm or [Mode] to cancel and return to the menu. - Display-reverse With this function, you can rotate the display by 180°. Use the [Up] and [Down] buttons to select "normal display" or "display turned by 180°" and press [Enter] to confirm or [Mode] to cancel and return to the menu.
- continuous controlling of the fan speed This mode is similar to "Auto", but the initial level of the fans speed can be adjusted by the DMX. - low speed/Switch Off the lamp operating The fans keep the adjusted low speed until the temperature exceeds max. inside temperature of the fixture, then the IMAGE SPOT 250 AT automatically switches Off the lamp. - low/high speed of the fan operating The fans keep the adjusted low speed until the temperature exceeds max.
8.5.Switching On/Off the lamp Press the [Mode] button in order to access the main menu. Browse through the menu by pressing the [Up] and [Down] buttons until the display shows "LAMP". Confirm by pressing [Enter] button. Use the [Up] and [Down] buttons to select "On" to switch On the lamp and "Off" to switch Off the lamp and press [Enter] to confirm or [Mode] to cancel. 8.6.
-Presetting playback This function allows you to select the the program which will be played in the stand-alone mode after switching the fixture on( LAAu-function must be "On" in the menu LAPr) .The selected program will be also used for the operating with the time periods or the light level period( LAAu-function must be "OFF" in the menu LAPr).
-Timer 2 -start This function sets the start of the time period 2.Use the [Up] or [Down] buttons to specify the start hour and press the [Enter]-button.Use the [Up] or [Down] buttons to specify the start minute and press [Enter]. -Timer 2-stop This function sets the finish of the time period 2.Use the [Up] or [Down] buttons to specify the stop hour and press the [Enter]-button.Use the [Up] or [Down] buttons to specify the stop minute and press [Enter].
How to set the light level operation: 1.Set LAAu-function to "Off"(menu PerS,submenu LAPr) . 2.Set the start and stop light levels for fixture operating (menu StAL,submenu LiGt). 3.Choose the desired running program (menu StAL,submenu Auto). 4.Deactivate the timer 1 and timer 2 (menu StAL,submenu timr). Note:The light sensor has the 2 minutes delay for the start/stop of the light level operation to eliminate the random light fluctuations.
next prog. step ,parameter "P.End" is increased about 1 automatically (except step 99). 5. Press Enter]-button to confirm adjusted value . 6. Press [Mode]-button,select next prog. step and repeat this procedure (steps 4 and 6). The editting programs "PrG.1,PrG.2,PrG.3" are saved in the current modified fixture (master or slave1-9). 8.8.Reset function Press [Enter] button to run a reset. This option enables the IMAGE SPOT 250 AT to index all effects (functions) and return to their standard positions. 8.9.
-- Fixture code The option contains identification code (1-9999) for the fixture, which is used for the master/slave operation. - Adjusting the default positions of gobo wheels By this function you can calibrate and adjust the gobo wheels to their standard/right positions. Disconnect the controller.
9.Error and information messages This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The IMAGE SPOT 250 AT will store this information and automatically ignite the lamp when the 5 minutes period has expired. Caution: The message is disabled if the lamp light sensor (function "En.Sn.
10.Technical specifications Power supply EU-model: Fuse: US-model: Fuse: Power consumption: 208/230/240V AC, 50/60Hz ~ T 3.15A @ 230V 100/120/208/230/240V AC, 50/60Hz ~ T 6,3A @ 120V 430 VA Remote control: 2 batteries 1,5V, size AAA Lamp MSD 250/2 GY-9,5 Optical System - High luminous-efficiency parabolic mirror and double condenser system - All lenses are anti-reflection coated -15° standard objective Rotating gobos - 5 gobo holders for 5 gobos - Gobo indexing - Rotating gobo-wheel cont.
2 truss orientation Safety chain/cord attachment point Temperatures Maximum ambient temperature : 45° C Maximum housing temperature : 80° C Minimum distances: Min.distance from flammable surfaces: 0,5m Min.distance to lighted object: 1,3m Dimensions and weight Weight (net):20 kg Beam path Optional accessories Mounting plate..............................................
11.Maintenance and cleaning The operator has to make sure that safety-relating and machine-technical installations are inspected by an expert after every four years in the course of an acceptance test. The operator has to make sure that safety-relating and machine-technical installations are inspected by a skilled person once a year.
batteries bottom cover Should you need any spare parts, please use genuine parts. If the power supply cable of this device will be damaged (cable firmly connected with the device), it has to be replaced by authorized dealers only in order to avoid hazards. If the power supply cable of this device will be damaged (replaceable cable), it has to be replaced by a special power supply cable available at your dealer. Should you have further questions, please contact your dealer. Version 1.