SPOT 250 XT Table of contents 1. Safety instructions ......................................................................................................... 3 2.Operating determinations .............................................................................................. 4 3. Description of the device .............................................................................................. 5 4. Installation .....................................................................................
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FORYOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
2.Operating determinations This device is a moving-head spot for creating decorative effects and was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. Never run the device without lamp! Do not shake the device. Avoid brute force when installing or operating the device.
3.
4. Installation 4.1Fitting the lamp DANGER ! Install the lamps with the device switched off only. Unplug from mains before ! To insert the lamp MSD 250 or MSD 250/2 open the top cover of the head (see the drawings to identify which cover is top) by loosening the 4 Phillips screws on the front and rear sides of the top cover.Then open the small lamp cover by loosening 3 fastening screws (see the drawing).If changing the lamp, remove the old lamp from the socket. Insert the lamp to the socket.
4.2 Lamp adjustment Correct Incorrect Keep optimum distance to lens Optimum distance 1 - 1,5mm Screw "A" Screw "B" The SPOT 250 XT lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve light performance. Strike the lamp and focus the light on a flat surface (wall).
Optional 18°-lens: Unscrew the knurled-head screw on the plate of the light-output. Install the optional 18°-lens and fix it with the knurled-head screw. 4.4 Inserting/Exchanging gobos DANGER! Install the gobos with the device switched off only. Unplug from mains before! To insert the gobos open the top cover of the head by loosening the 4 Phillips screws on the front and rear sides of the top cover.
4.5 Rigging the fixture Danger of fire ! When installing the device, make sure there is no highly inflammable material (decoration articles, etc.) in between a distance of min. 0,5 m. Warning ! Use 2 clamps to rig the fixture on the truss. Follow the instructions mentioned at the bottom of the base. Make sure that the device is fixed properly! Ensure that the structure (truss) to which you are attaching the fixtures is secure.
Fixation via a mounting plate 1. Screw 2 clamps (1) to the mounting plate (4) with M12 bolts and lock nuts through the holes in the mounting plate (4). 2. Insert the 4 quick-lock fasteners (3) into the holes on the bottom of the base and tighten fully clockwise. 3. Fasten the safety-rope (2) through the two apertures on the bottom of the base and over the trussing system.
4.6 Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency. The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed next to the power switch. Verify the power supply settings before applying power! If you want to change the power supply settings,follow the instructions: 1.Disconnect the fixture from AC power. 2.
4.7 Connection to the mains Connect the fixture to the mains with the enclosed power cable and plug. The earth has to be connected! The occupation of the connection-cables is as follows: Cable (EU) Cable (US) Pin International Brown Black Live L Light blue White Neutral N Yellow/Green Green Earth 4.8 DMX-512 connection/connection between fixtures The wires must not come into contact with each other, otherwise the fixtures will not work at all, or will not work properly.
5. DMX PROTOCOL Mode 1 Mode 2 8 bit Value channel channel channel 1 1 1 2 3 4 5 6 7 3 2 2 4 5 6 7 3 proportional Tilt 0-255 Tilt movement by 280° proportional Pan fine 0-255 Fine control of pan movement proportional Tilt fine 0-255 Fine control of tilt movement proportional Speed of PAN/TILT movement 0 Max. speed (tracking mode) 1-249 From max. speed to min.speed (vector mode) 250-255 Max.
Mode 1 Mode 2 8 bit Value Function Type of control channel channel channel 9 9 10 10 11 12 11 12 7 224-231 232-239 240-247 248-255 Macro 9 Macro 10 Macro 11 Macro 12 step step step step 0 1-126 127-128 129-255 3 facet prism rotation control No rotation Forwards rotation from fast to slow No rotation Backwards rotation from slow to fast step proportional step proportional 0-31 32-63 64-95 96-127 128-159 160-191 192-223 224-255 Rotating gobos Open Rot. gobo 1 (multicolour dichroic) Rot.
6. Controller mode The fixtures are individually addressed (001-497) on a data link and connected to the controller.The fixtures respond to the DMX signal from the controller. 6.1 DMX addressing The control panel on the front panel of the fixture allows you to assign the DMX fixture address, which is defined as the first channel from which the SPOT 250 XT will respond to the controller. If you set, for example, the address to channel 5, the SPOT 250 XT will use the channel 5 to 20 for control.
Focus Motorized focus enables the beam to be focused anywhere on stage. Dimmer/Shutter/Strobe Smooth 0 - 100 % dimming is provided by the combined mechanical dimmer/shutter unit. This unit may also be used for strobe effect (1 - 10 flashes per second) Fans The SPOT 250 XT is cooled by three axial fans - two in the projector head and one in the base. The speed of the fans (and of course the noise) can be continuously reduced if very quiet performance is required.
8. Functions of the control panel The control panel situated on the front side of the base offers several features. You can simply set the DMX address,master/slave mode, read the number of lamp or unit hours, switch On and Off the lamp, run test, make a reset and also use many functions for setting and service purposes. The main menu of the control panel is accessed by pressing the [Mode] button - press this one so many times until the display shows message "A001" (with actually stored address).
to confirm. If you want address no master or slave, select "d.AbL.". 4. Press the [Mode]- button.Choosen address is shown on the display. If message "MASt." fast flashes-DMX signal is received at the DMX-input- disconnect DMX controller! Only one fixture may be the master. Up to the 9 slaves may be connected to the master and on the certain address can be connected only one slave fixture (SLA1-SLA9).
- The number of the hours that the SPOT 250 XT has been powered On since the counter was last reset.Press [Enter] or [Mode] to return to the menu.In order to reset this counter to 0, you have to hold the [Up] and [Down]-button and press the [Enter]button. Lamp On time - This option enables you to read the total number of the operation hours with the lamp on since the SPOT 250 XT has been fabricated.Press [Enter] or [Mode] to return to the menu.
Software version By this function you can read the software version of the display module. Press [Enter] to read its value or [Mode] to return to the menu. 8.4 Personality options These options allow you to modify SPOT 250 XT operating behavior. Press [Up] and [Down] buttons to select the desired option and press [Enter] to set the value or to see next submenu. Pan reverse This function allows you to invert the pan movement.
List of the channel settings: Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Mode 1-16bit (default) Pan Tilt Fine Pan Fine Tilt Pan/Tilt speed Fans, On/Off lamp Colours No function Prism Prism rotation Rotating gobos Rot.gobo rotation No function Focus Shutter, strobe Dimmer Mode 2-16bit Pan Fine Pan Tilt Fine Tilt Pan/Tilt speed Fans, On/Off lamp Colours No function Prism Prism rotation Rotating gobos Rot.
Lamp Off if DMX is missing This function allows you to switch Off the lamp automatically after 2 minutes if DMX signal is missing on the data link. Use the [Up] and [Down] buttons to select "On" if you want to switch Off the lamp or "Off" if you don’t want to switch Off the lamp and press [Enter] to confirm or [Mode] to cancel and return to the menu.
tilt-position for a short moment). Use the [Up] and [Down] buttons to select "On" if you want to execute the blackout or "Off" if you don’t and press [Enter] to confirm or [Mode] to cancel and return to the menu. PAN/TILT-feedback This function allows to return the mowing head to the required pan/tilt position after changing the position by external force (e.g.by stroke).
Default settings Press [Enter] to reset all fixture personalities (not the adjusting functions) to the default values. On the display will appear "rSt" meaning that the fixture makes the reset. See the table of personality setting and their default positions. Personality Display Default values (SHADED) Pan reverse Tilt reverse Movement resolution Lamp On after switch. the fixture On Lamp Off via DMX Lamp On if DMX is present Lamp Off if DMX is missing Blackout during mov.
8.6 Test sequences This function allows you to run a special demo-test sequences without an external controller, which will show you some possibilities of using SPOT 250 XT. Press [Up] and [Down] keys to select the "Mod1" or "Mod2" sequences. The "Mod1" is suitable for projections on the wall, ceiling or ground without any head-movement, the "Mod2" uses all SPOT 250 XT functions and therefore is good for a complete introduction of the fixture.
This option should be set "OFF" for all slaves in the master/slave chain by reason of the right program starts. For example: You have selected program "PrG.3" in this menu and: this fixture is set as a single fixture (master/slave or controller operating)- the fixture will run its program "PrG.3". this fixture is set as a master in a data chain- the fixture will run its program "PrG.3".
5. Press Enter]-button to confirm adjusted value . 6. Press [Mode]-button,select next prog. step and repeat this procedure (steps 4 and 6). The editting programs "PrG.1,PrG.2,PrG.3" are saved in the current modified fixture (master or slave1-9). 8.8 Reset function Press [Enter] button to run a reset. This option enables the SPOT 250 XT to index all effects (functions) and return to their standard positions. 8.
Fixture code The option contains identification code (1-9999) for the fixture, which is used for the master/slave operation. Adjusting the default positions. of colour, gobo and effect wheels By this function you can calibrate and adjust the colour, gobo and effect wheels to their standard/right positions.
DMX Calibration protocol: DMX chanel Function 1 Colour 2 No function 4 Rotating gobo 6 No function 3 5 7 S m o o t h Effect Gobo rotating m i c r o s t e p m o v e m e n t Calibration 0-255 Calibration 0-255 Calibration 0-255 Calibration 0-255 Colours Standard protocol Effect(prism) Standard protocol 11 Rotating gobos Standard protocol 13 No function 8 9 10 12 14 15 16 No function Prism rotation Gobo rotation Standard protocol Standard protocol Focus Standard protocol Dimm
FAn The message informs you that the fixture was overheating and switched off. This message will appear on the display if the fan speed operating "LOOF" was selected. MbEr This messsage informs you that the main PCB does not communicate correctly with the Control Board. CoEr (color-wheel error) The messsage will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB).
10. Technical specifications Power supply: EU-model-Voltage......................208/230/240V AC, 50/60 Hz ~ -Fuse.........................T 3.15 A@230V US-model-Voltage......................100/120/208/230/240 V AC, 50/60 Hz ~ -Fuse.........................T 6.3 A@120V -Power consumption....500 VA Lamps: -Philips MSD 250 or MSD250/2 GY9.
Colours: -Color-wheel with 11 dichroic filters plus open -Colour-wheel continuous rotation in both directions (rainbow effect) -Via the combination between multicolour dichroic gobo and color-wheel even more colour combinations possible Rotating gobos: -Rotating gobo-wheel with 6 interchangeable and indexable rotating gobos plus open -Rotating gobo-wheel cont.
8 9 10 11 12 13 14 15 16 No function Prism Prism rotation Rotating gobos Rot.gobo rotation No function Focus Shutter, strobe Dimmer No function Prism Prism rotation Rotating gobos Rot.gobo rotation No function Focus Shutter, strobe Dimmer Pan/Tilt -Pan movement range 530° -Tilt movement range 280° -8/16 bit movement resolution -Automatic Pan / Tilt position correction -Maximum PAN-movement 530° in 2.65 s -Maximum TILT-movement 280° in 1.
Accessories - Accessories gobo-set 1.................................15050010 - Omega holder (2 pieces)................................99010420 Optional accessories: Objective12°.........................................99010201 Lens-module 18°...................................99010200 Mounting plate......................................99010500 11.