Specifications

17
5.Set the program running options (Menu path: "St.A."--->"C.S.A.") on the master and slaves:
For time control of the xtures select item "tiM" on the master and all slaves.
For audio control of the xtures select item "Au.P." on the master and all slaves.
For audio random selection of effects ,select item "Au.r" on the master and all slaves.
6.Set the lamp automatically On after switching the xtures on (Menu path: "LA.P."--->"LA.A."--->On) and check
that function d.OF is disabled (Menu path: "LA.P."--->"d.OF"--->OFF)
Note: Master-slave operation is only possible among xtures: Euphoria,ClubScan 150,ClubScan
250,Funky,Fusion and Hip-Hop.
10. Error and information messages
M.Er.(Master error)
The message informs you that the xture was addressed as a master and DMX signal is connected to its
input.Disconnect the DMX controller from xture's input and reset the xture.
F.Er.
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices. In these cases the message does not affect the xture operating!
11.Technical specications
Power supply:
-Voltage......................100,120,208,230 ,240V AC, 50/60Hz ~
-Fuse..........................T 1,6 A@ 230V
-Fuse..........................T 3,15 A@ 120V
-Power consumption...250 VA
Lamp:
- ELC / 24V/250W
- Socket: GX5.3
Optical System:
- Manual focus
- Rotating triangular prism
- Static triangular prism
Gobo wheel:
- 9 static gobos
- gobo shake
Strobe:
- Strobe effect with variable speed (max.4 ashes per second)
Motor:
- 2 high quality stepping-motors controlled by microprocessors
Electronics:
- Intelligent control panel with 3-digit LED display
- Digital serial input DMX-512
- 3 control channels:
Channel 1: Gobo wheel
Channel 2: Triangular prism rotation
Channel 3: Dimmer
- Time and audio trigger
- One editable program