8. Functions of the control panel
The control panel situated on the top cover of the xture offers several features. You can simply set the DMX
address or master (slave) mode,switch On and Off the lamp,run a test,make a reset and also use other func-
tions for setting xture behaviour.
Control elements on the control board:
[ENTER] button- enters menu,conrms adjusted values and leaves menu.
, [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
In order to leave the menu without saving value,press [UP] and [DOWN ] at the same time.
After switching the xture on,the display shows the initial DMX address:
Use [UP],[DOWN] to browse through the menu. To select a function or submenu,press [ENTER].
8.1 Fixture Address
Use this menu to set the DMX address of the xture which is dened as the rst channel from which the xture
will respond to the controller.
For address setting follow this procedure:
1. Switch On the xture and wait until the xture reset has nished ("rES" is ashing at the display).
2. Browse through the menu by pressing the [UP] and [DOWN] keys until the display shows current addres
"001".Conrm by pressing [ENTER] key and "001" will start to ash frequently.
3. Use the [UP] and [Down] keys to select the desired address.
4. Conrm by pressing [ENTER].
After having addressed xture, you may now start operating xture via your lighting controller.
8.2 Microphone sensitivity
Select this function to adjust the microphone sensitivity from 1(maximum) to 20(minimum).
8.3 Lamp On/Off
Select this item to switch the lamp on/off.
Note:if DMX signal is present on the data link,the lamp will be switched automatically on.
8.4 Lamp preseting
Select this menu to change the lamp "behaviour".
LA.A. --- Strike lamp automatically.Select this function to turn the lamp on automatically after switching the
xture on.
d.OF. --- Lamp OFF if DMX is missing. This function allows you to switch Off the lamp automatically if DMX
signal is missing on the data link.