Version 1.
Euphoria Table of contents 1. Safety instructions.......................................................................................................... 3 2. Operating determinations............................................................................................... 4 3. Description of the device................................................................................................ 5 4. Installation................................................................................
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
2. Operating determinations This device was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. When taking the device into operation, please make sure that the housing is closed firmly with all the necessary screws tightened up.
3.
4. Installation 4.1Fitting/Exchanging the lamp DANGER ! Install the lamps with the device switched off only. Unplug from mains before ! 1.Disconect the fixture from mains and allow the fixture to cool at least 15 minutes. 2.To insert the lamp remove the top cover by loosening the 3 quarter-turn fasteners on the top cover. 3.Caution remove the display module (1) by loosening two fastening screws (2). 4.Grasp the lamp by the reflector (3) and pull it out of the lamp holder (4). 5.
4.2 Changing the power supply setting The transformer must be connected correctly for the local AC voltage and frequency. The wrong setting can cause poor performance or demage of the fixture.The factory settings are printed on the rear panel of the fixture. If you want to change the power supply setting,follow the instructions: 1.Disconnect the fixture from AC power. 2.Remove the top cover by loosening the 3 quarter-turn fasteners on the top cover. 3.
under high working places and other endangered areas is forbidden. The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time. The operator has to make sure that safety-relating and machine-technical installations are approved by an expert after every four year in the course of an acceptance test.
4.5 DMX-512 connection and Master/Slave connection Controller operation Master/slave operation The fixture is equipped with 3-pin XLR sockets for DMX input and output. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
5. Euphoria - DMX protocol,version 1.
6. Controller mode The fixtures are individually addressed on a data link and connected to the controller.The fixtures respond to the DMX signal from the controller. 6.1 DMX addressing The control panel on the front panel of the fixture allows you to assign the DMX fixture address, which is defined as the first channel from which the Euphoria will respond to the controller. If you set, for example, the address to channel 4, the Euphoria will use the channel 4 to 6 for control.
7. Euphoria - Control menu map Default settings=Bold print 001 (001-510) MI.S. (01..10..20) LMP (OFF,On) LA.P. LA.A. (OFF,On) d.OF. (OFF,On) tSt St.A. run St.M. OFF MSt SLA Aut (OFF,On) C.S.A tiM. Au.P. Au.r. Pr.E. E.01 : E.30 SPE. VEr. UPd. r.tG (0-255) Gob. (0-255) diM. (0-127) tiM. (0.0-25.5s) COP. End No YES Adj. Gob. (0-255) r.tG. (0-255) diM. (0-127) CAL.
8. Functions of the control panel The control panel situated on the top cover of the fixture offers several features. You can simply set the DMX address or master (slave) mode,switch On and Off the lamp,run a test,make a reset and also use other functions for setting fixture behaviour. Control elements on the control board: [ENTER] button- enters menu,confirms adjusted values and leaves menu. , [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
8.5 Demo-test sequences Use the item to run a special demo-test sequences without an external controller,which will show you some possibilities of using the fixture. 8.6 Stand-alone setting Select this menu to set fixture behaviour in stand-alone mode. run --- Running program.Select this menu to run a program in a loop or to generate random effects. St.M. --- Stand-alone mode.This function allows you to set the fixture as master or as slave: OFF. --- The option disables Master/slave operation.
The following are required in order to update software: - PC running Windows 95/98/2000/XP or Linux - DMX Software Uploader - Flash cable RS232/DMX (No.13050624) Note1:Software update should execute a qualified person.If you lack qualification, do not attempt the update yourself and ask for help your ROBE distributor. Note 2:DMX address,program and all settings will be set to their default values To update software in the fixture: 1.Installation of DMX Software Uploader: 1.
9. Stand - alone mode The fixtures on a data link are not connected to the controller but can execute pre-set program which can be different for every fixture."Stand-alone operation" can be applied to the single fixture (the fixture may be set to the master or slave mode ) or to multiple fixtures operating synchronously.Effect actions are triggered by sound,using built-in microphone, or automatically using an internal timer.
5.Set the program running options (Menu path: "St.A."--->"C.S.A.") on the master and slaves: For time control of the fixtures select item "tiM" on the master and all slaves. For audio control of the fixtures select item "Au.P." on the master and all slaves. For audio random selection of effects ,select item "Au.r" on the master and all slaves. 6.Set the lamp automatically On after switching the fixtures on (Menu path: "LA.P."--->"LA.A."--->On) and check that function d.OF is disabled (Menu path: "LA.P.
Temperatures: -Maximum ambient temperature : 40° C -Maximum housing temperature : 65° C Minimum distances: -Min.distance from flammable surfaces: 0,4m -Min.distance to lighted object: 0,6m Dimensions and weight: - Weight: 7.5 kg 12. Maintenance and cleaning DANGER TO LIFE! Disconnect from mains before starting maintenance operation! It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or within the fixture.