Specifications

DigitalSpot 7000 DT
27
Lamp On Time --- Select this submenu to read the number of the operation hours with the projector lamp on.
Total Hours -
The function shows the total number of the operation hours with the lamp
on since
the
DigitalSpot 7000
has been fabricated.
Resetable Hours -
The function shows the number of the operation hours with the
lamp on that
the
DigitalSpot 7000
has been powered on since the counter was last reset.
In order to reset this counter to 0, press [ENTER] twice.
Lamp Strikes --- Select this submenu to read the total number of the projector lamp strikes.
Total Hours - The function shows the total number of the lamp strikes since
the
DigitalSpot 7000
has been fabricated.
Resetable Hours - The function shows the number of the lamp strikes since
the counter was last reset. In order to reset this counter to 0, press [ENTER] twice.
Fixture Temperatures --- Select this submenu to read the temperatures of the projector:
Current - Select this function to read the current temperatures of the fixture interior .
Maximum nonresetable -The function shows the max. temperatures of the fixture interior
since the DigitalSpot 7000 DT has been fabricated.
Maximum resetable - The function shows the maximum temperatures of the fixture interior
since the respective counter was last reset. In order to reset desired counter to 0,
press [ENTER] twice.
Measuring points of temperatures:
Projector temp.1 [°C] ]………….temperature measured in the data projector
Projector temp.2 [°C]…………..temperature measured in the data projector
Projector temp.3 [°C] ]…………..temperature measured in the data projector
Pan /Tilt Board. [°C] ...............temperature on the PCB in the fixture base
Led Panel Board 1 [°C]............temperature in the LED module 1
Led Panel Board 2 [°C].............temperature in the LED module 2
Air Filters --- Regular cleaning of the air filters is very important for the DigitalSpot 7000 DT life and performance.
Buildup of dust, dirt and fog fluid residues reduces the fixture´s light output and cooling ability. The two items of
menu help you to keep cleaning period of the air filters.
Time To Cleanup Filters - The option allows you to read the time which remains to
cleaning air filters. Expired time period is signalized by a negative mark at the time value and
a warning icon (triangle) on the display with the following message:
"Please , Clean Up Airs Filters."
Clean the filters and reset this menu item (by pressing the "Enter" button twice while
this menu is highlighted)
Set Cleanup Timer - Cleaning schedule for the fixture depends on the operating
environment. It is therefore impossible to specify accurate cleaning interval. This function
allows you to change the cleaning interval of the air filters. This "reminder" value is
50 hours and it is set as default. Inspect fixture within its 50 hours of operation to see
whether cleaning is necessary. If cleaning is required, clean all air filters and change
the value in this menu on acceptable level. Min. level is 10 hours, max. is 300 hours.
Dataprojector Service --- The menu includes items related to the dataprojector filter.
Filter Used Time
The counter shows the total accumulated time of the filter use.
Remaining Filter Scroll -
The counter
shows the number of remaining scrolls of the filter.
When this counter is counted down to 0, the filter carttridge replacement is necessary – see
the chapter “
Replacing the filter cartridge in the projector”.
Air Pressure Sensor -
The function
shows the air pressure measured behind the air filter.
15.10 Special functions
Use this menu for special services like remote servis or software update.
Regenerate Thumbnails --- Use the menu to manage thumbnails behaviour.
Set Thumbnail size - The menu item allows set the size of the thumbnail: 50-min.size,