Specifications

15
Lamp Off via DMX
This function allows you to switch Off the lamp by DMX. Use the [Up] or [Down]-key to select "On" if you want
to switch Off the lamp by DMX or "Off" if you don’t want to switch Off the lamp by DMX and press [Enter] to
confirm or [Mode] to cancel and return to the menu.
Temperature
Temperature readouts of fixture inside in Celsius. Inside temperatures below 80° C are not critical. 80° C and more
lead to the lamp being switched off. Please note that the outside temperature should not exceed 45° C.
Fan speed operating mode
By using this function you can choose 4 types of fan speed operating modes. Browse through this menu by the
pressing [Up] or [Down]-keys - the display shows step by step these messages: "HIGH, reG, Lo.OF, Lo.HI,".
Press [Enter] if you wish to select one of them or [Mode] to cancel and return to the menu.
high (max) speed of the fan
The cooling fan works on max. speed (max. cooling)
continuous controlling of the fan speed
the fan automatically raises its speed in order to control inside temperature of the lighting,
if the temperature inside increases about certain level (the low fan speed reduces the cooling of the
lighting).This cycle can repeat several times until the temperature inside is on suitable level.
low speed/Switch Off the lamp operating
the fan keeps the adjusted low speed until the temperature exceeds max. inside temperature, then the
BEAM 250 XT automatically switch Off the lamp.
low/high speed of the fan operating
the fan keeps the adjusted low speed until the temperature exceeds max. inside temp.of the fixture,
then the BEAM 250 XT automatically switches from low to high the fan speed.