Specifications
29
t.M.Er.(Temperature measuring error)
The message informs you that the communication betwen the head and the main board in the xture base was
cut off (or the head temperature sensor is defective) and the lamp was automatically switched off.
13. Technical specications
Power supply:
EU-model-Voltage......................208/230/240V AC, 50/60Hz ~
-Fuse.........................T 3.15 A@230V
US-model-Voltage......................100/120/208/230 V AC, 50/60Hz ~
-Fuse.........................T 6.3 A@120V
-Power consumption....405 VA
Lamp:
Philips MSD 250/2,GY-9.5
Optical System:
- High luminous-efciency parabolic reector
- Front fresnel lens of diameter 158 mm
Colour wheel:
-6 replaceable 'SLOT&LOCK' dichroic lters (including 6000K and 3200K CTF and UV lter)
+ open
Effects:
-Beam shaper
-Frost lter for softer beam
Zoom
- zoom range: 8°-32°
CMY-colours mixing module
- Smooth CMY colour mixing system
- 30 colour macros
Strobe:
- Strobe effect with variable speed (max.15 ashes per second)
Dimmer:
- Smooth dimmer from 0 - 100 %
Motors:
- 10 high quality stepping-motors controlled by microprocessors
Electronics:
-Addressing,special functions setting,effects calibration via control panel with 4-digit LED
display
-Readout xture and lamp usage,receiving DMX values,temperature, etc
-Built-in analyzer for easy fault nding,error messages
-Remotely switching on/off the lamp
-Bilt-in demo sequences
-Black-out while head moving or color changing
-Silent fans cooling,
-Self-resetable thermo-fuse
-Master/slave operation
-Digital serial input DMX-512, RDM support
-4 control-channels presettings (18,16,20,18 control channels)
-Support RDM
Pan/Tilt
-Pan movement range 530°