Use and Care Guide
Troubleshooting of General faults
Plug in the power plug
Replace the light or plug in the plug
Use single-phase three-pole 
socket and well grounded
Tighten the cap
Adjust the body to the horizontal state
Cause
Fault
Serial 
number
Warning
The light is damaged or 
poorly connected
The impeller is loose, and the 
cap is not tightened
The power plug is not connected 
properly or there is power failure
The power socket is not 
grounded well
No response after pressing any icon
(e.g. the impeller does not rotate, 
or the light is off)
Pressing the lighting icon, the
 headlamp is not lit
Induced current exists on the hood
 body may paralyze hands
Abnormal sound during impeller running
1
2
3
4
 No oil in the oil cup after a 
period of time
The hood body is tilt
5
Solution
1.When connecting or replacing the plug, please unplug the power plug.
2.If the range hood's power cords are damaged,it must be replaced by our company's professional 
 maintenance staff.
 Range Hood