Installation guide
RoadRunner Installation Guide
Connections: External Recording Triggers
1331-118th Ave SE, Ste 300 - Bellevue, WA 98005
Tel: 425.453.0430 / Fax: 425.453.0959
www.avt-usa.com
Page 8
It may be necessary or preferable to use switches, doors or other triggers to initiate recording.
READ THE FOLLOWING PRIOR TO INSTALLATION
Any 12 VDC or higher ouput MUST use
the supplied relay or damage to the DVR
can result.
Devices which go to Ground when
activated do not require the relay and
may be connected directly to the DVR
alarm inputs.
Many devices besides door switches or
indicators may be used as recording and
event log triggers.
Up to three external devices can be used
as Recording and Event log triggers.
Some software set-up is required; see
RoadRunner manual for more information.
Alarm input 4 is reserved for the optional
Panic Button.
STOP
Relay Connections:
85 From 12 VDC trigger
86 To DVR alarm ground
30 Tied to 86
87 To DVR alarm input 1, 2 or 3
From 12 VDC output
87
86
30
85
To DVR alarm ground input
To DVR alarm input 1, 2 or 3
Supplied Relays
and connectors