Specifications
Page52
PLUMBINGSYSTEM(continued)
Problem Cause Solution
SHOWER–seepage30
Nowateratshowerhead
Valveatshowerheadisturnedoff Openvalveatshowerhead
Lackofwater Turn on pump, check city water
hookuportanklevel
Water backs up into shower while
runningkitchenorbathfaucet
Graywatertankisfull Emptythegraywaterholdingtank
Water backs up into shower while
usingit
Graywatertankisfull Emptythegraywaterholdingtank
Showerdrainbasketisplugged Cleanoutshowerdrainbasket
WASTEWATER–seepage30
Wastetankwillnotdrain
Emptywastetank Checkforwaterintankattoilet
Drainpipeplugged Insert a wire to unclog from the
outside – CAUTION: sudden
discharge
Contentsintankarefrozen Dumpinwarmerclimate
Wastewatervalveis broken Callthetechnicalhotlinenumberon
page3
Grey water is backing up into
shower/tub
Fullwastetank
Emptythegreywaterholdingtank
Monitorpanelshowsfullorregisters
morethanemptyafterdumping
Wasteisstuckonthesensors Fill tanks with about 3 buckets of
clean water and some chemical.
Driving should clean off the excess
waste
REFRIGERATOR –seepage23
Problem Cause Solution
CHECKlighton/GASlightblinking
Temporarymalfunction Turnoff andwait45secondsbefore
turningitbackon
Otherproblemsdescribedbelow Turn off and remedy situations as
describedbelow
Refrigeratorisoff Turnedoff Turniton
Noorlow12VDCpower Turnbatterydisconnecton/recharge
auxiliarybatteries
Fuseblown Checkandreplacefuse
Refrigeratornotcooling Motorhomenotlevel Level out motor home and turn off
refrigeratorforanight.Problemmay
persistandrequirealargerrepair
Outofpropaneormainvalveclosed Fillpropanetankoropenmainvalve
Reducedcooling Outsideextremelyhot Moveoutofsunshine
Climatecontrolswitch“ON” Turnswitchoff
Temperature sensor not properly
adjustedorhangingloose
Adjusttemperaturesensor
Motorhomenotlevel Leveloutmotorhome