Troubleshooting guide

80
System: Funmover liftgate
Problem Possible Cause Check/Solution
Liftgate will not go up or
down, just stuck in place.
1) Low auxiliary battery.
2) Breaker tripped for lift
gate.
3) Remote cord connection
loose at the coach.
1) Engine should be running
any time the lift gate is in
use.
2) Reset the breaker located
next to or above the auxiliary
battery in the generator
compartment.
3) Try to wiggle the
connector while pushing
buttons on the remote.
System: Furnace
Problem Possible Cause Check/Solution
Furnace blows cold air. 1) Unit is out of LPG.
2) Main LPG valve is off.
LPG detector is off.
3) There is air in the LPG
lines.
1) Refill the LPG tank.
2) Turn on the main LPG
valve.
3) Reset the LPG detector.
Turn the furnace on and off
several times, waiting 30 to
45 seconds between cycles
or light the stove burners and
let run for a few minutes.
Furnace does not work at all. 1) Blown fuse in power
converter.
2) Low auxiliary battery.
3) Dust in the wall
thermostat.
1) Replace the 15a fuse in
the power converter, or the
2a fuse in the wall
thermostat.
2) Run the engine battery for
20 to 30 minutes to recharge
the auxiliary battery.
3) Open the cover of the
thermostat. Use a
screwdriver to clean out dirt
particles between the
contacts.