Troubleshooting guide

77
This troubleshooting section is intended to be a general guideline. For detailed help, please
call our Roadside Assistance number 800-367-4707.
System: 110V Power
Problem Possible Cause Check/Solution
Generator running but no
110V power in the coach.
1) Generator breaker tripped.
2) Breakers in power
converter tripped.
3) Shore line not plugged
into the receptacle in the
shore line compartment in
models without automatic
transfer modules.
1) Reset the breaker on the
generator.
2) Reset the breakers in the
power converter.
3) Plug the shore line into the
receptacle in the shore line
compartment.
Plugged into shore power but
no 110V power in coach.
1) Breaker at shore power
hook up is off.
2) Breakers on the generator
are off.
1) Reset the breaker in the
shore power box.
2) Reset the breakers on the
generator.
Microwave and A/C work but
no 110V power to outlets.
1) GFI circuit is tripped.
2) Power converter breakers
are tripped.
1) Reset the GFI outlet in the
bathroom and/or the kitchen.
2) Reset the breakers in the
power converter.
System: 12 Volt Power System
Problem Possible Cause Check/Solution
No power to appliances or
amenities.
1) Low auxiliary battery.
2) Blown fuses in the battery
compartment.
3) 40 amp breaker needs to
be reset or needs to cool
down.
4) Battery disconnection
switch at side door entrance
is off.
1) Run the engine battery for
20 to 30 minutes to recharge
the auxiliary battery.
2) Replace blown fuses.
3) Reset the 40 amp breaker.
4) Reset the battery
disconnection switch to the
ON position.