Specifications

38
4.3. L.P. Gas System
LP GAS / PROPANE GAS SYSTEM
Problem Cause Solution
Smell LP Gas in and/or
around unit
Possible gas leak in system Extinguish any open flames, pilot
lights and all smoking material
Do not touch electrical switches
Shut off the gas supply at the
tank valve
Open doors and other ventilating
openings
Leave the area until odor clears
Have the gas system checked
and leakage source corrected
before using again
LPG detector alarm going
off
LP Gas in coach Air out coach and try to reset the
detector. If unable to reset, call
Roadside Assistance
Low auxiliary battery Recharge auxiliary battery by
starting engine or hooking up
FURNACE
Furnace does not light May be out of LP gas or valve
closed
Fill LP gas tank or open valve
Low battery Recharge battery
No 12V power Turn battery disconnect on
Furnace fan does not run Blown fuse Replace fuse at power center
WATER HEATER
Water Heater not working
or illuminated switch not lit
No 12V power Turn battery disconnect on
May be out of LP gas Fill LP gas tank
Water is already hot Check for hot water at faucet
REFRIGERATOR
Refrigerator not cooling Unit not level Make sure unit is level
Check LP gas level Fill LP gas tank or open valve
Check CHECK light Turn off and after 30 seconds
turn back on
Reduced cooling Outside extremely hot
Climate control switch “ON”
Unit not leveled
Move out of sunshine
Turn “OFF” switch
Level unit
Refrigerator is off Check on/off switch Turn on
Check battery 12V power Turn battery disconnect on
STOVE TOP
Stove burner will not light No LP Gas Check LP Gas
OVEN
Turned knob but oven won’t
light
Pilot light must be lit manually Turn oven knob to “Pilot” and
keep pushing it, then use match
or lighter to light pilot light