Installation guide

RO-MAN REVERSE OSMOSIS SYSTEM INSTALLATION GUIDE
RO-MAN.COM LTD Page 4 of 15
4
C
ONNECTING THE RED PIPE TO THE SADDLE VALVE IS NOT DIFFICULT, REMOVE THE NUT FOR THE VALVE
AND PUT IT OVER THE PIPE
, THEN PUSH THE SMALL COPPER RING OVER THE END OF THE PIPE AND PUSH
THE INSERT INTO THE END OF THE PIPE
. THEN PUSH THE END OF THE PIPE INTO THE VALVE ASSEMBLY
AND TIGHTEN THE NUT
(DO NOT OVER TIGHTEN).
W
HEN FITTING THE VALVE MAKE SURE THE SADDLE VALVE IS IN OPEN POSITION. WITH A SPANNER FIT THE
SADDLE VALVE TO A
15/9 MM PIPE.
O
NCE THE SADDLE ASSEMBLY IS FITTED PUT THE OTHER END OF THE RED PIPE IN WATER CONTAINER
AND
CLOSE THE TAP ON THE SADDLE VALVE TO PIERCE THE PIPE, YOU MAY NEED TO OPEN AND CLOSE
THIS SEVERAL TIMES TO CLEAN THE BORE OFF
NOTE ON FIT CONNECTIONS QUICK CONNECTORS:-
PI PE
Q C FITTING
COLLET
THE PUSH FIT CONNECTORS ARE OPENED BY PUSHING DOWN ON THE COLLET RING WITH TWO
FINGERNAILS AND PULLING THE HOSE AT THE SAME TIME
. IF YOUR NAILS ARE NOT USER FRIENDLY, THEN
USE A PAIR OF PLIERS
, A SMALL SPANNER OR ANY TOOL THAT CAN APPLY PRESSURE ON BOTH SIDES OF
THE
QUICK CONNECTORS COLLET
F
ITTING THE MEMBRANE
MEMBRANE
HOUSING O RIN
G
“O” RINGS
PRO DUC T WATE
R
WASTE WATER
PRE- FILTERD
WATER
FI LTER
HOUSING CAP
MEM BRANE HO USING
NOTE
PLEASE ONE MEMBRANE AT A TIME
DISCONNECT THE GREEN TUBE THAT RUNS IN TO THE TOP MEMBRANE HOUSING
U
NPACK THE MEMBRANE. DO NOT REMOVE THE TAPE FROM AROUND THE MEMBRANE!