OUTPUT
PARAMETER CONDITIONS MIN TYP MAX UNITS
Output voltage accuracy 2
%
Output voltage adjustment
range
IS240-24
IS240-48
22-28
45-55
V
V
Output voltage can be adjusted within above range by V-ADJ. variable
resistance inside of the power supply. When output voltage exceeds
the range, the power supply will be in failure or get into over voltage
protection mode. To avoid the case that the output voltage is higher
than rated voltage, output current should be used under rated current
Minimum load 0
%
Line regulation Vin from 100Vac to 240Vac 2
%
Load regulat
ion Vout from min. to max. 3
%
Turn-on delay time Full load, Vin=115Vac 3600 ms
Hold up time Full load, Vin=115Vac 20
ms
PRODUCT SPECIFICATION
din rail power supply
www.pairuigroup.com
Page:4/17
PAIRUI ELECTRONICS
Updated 2016-V1.0-1207
RND 315-00011
Protection
Short circuit Hiccuo mode, it will recover automatically after fault condition is removed
Over voltage
IS240-24: over voltage protection value 33V
IS240-48: over voltage protection value 66V
(1) When output voltage exceeds above over voltage protection value or reversal
voltage occurs, the protection will be started and the output voltage will be cut
off in order to protect the power supply;
(2) The power supply will recover after the power is turned on again
Over current
IS240-24: over current protection value 11A
IS240-48: over current protection value 5
.5A
(1) When output voltage exceeds above over current protection value, the
protection will be started and the output voltage will be cut off in order to
protect the power supply;
(2) The power supply will recover automatically after the fault condition is
removed
Over
temperature
Over temperature protection value: 110±10℃
(1) When the ambient temperature exceeds above over temperature protection
value, the protection will be started and go into hiccup mode;
(2) The power supply will recover automatically after the fault condition is
removed
PRODUCT SPECIFICATION
din rail power supply
www.pairuigroup.com
Page:5/17
PAIRUI ELECTRONICS
Updated 2016-V1.0-1207
RND 315-00011:
Protection
Short circuit
Hiccuo mode, it will recover automatically after fault condition is removed
Over voltage
IS240-24: over voltage protection value 33V
IS240-48: over voltage protection value 66V
(1) When output voltage exceeds above over voltage protection value or reversal
voltage occurs, the protection will be started and the output voltage will be cut
off in order to protect the power supply;
(2) The power supply will recover after the power is turned on again
Over current
IS240-24: over current protection value 11A
IS240-48: over current protection value 5.5A
(1) When output voltage exceeds above over current protection value, the
protection will be started and the output voltage will be cut off in order to
protect the power supply;
(2) The power supply will recover automatically after the fault condition is
removed
Over
temperature
Over temperature protection value: 110±10℃
(1) When the ambient temperature exceeds above over temperature protection
value, the protection will be started and go into hiccup mode;
(2) The power supply will recover automatically after the fault condition is
removed
PRODUCT SPECIFICATION
din rail power supply
www.pairuigroup.com
Page:5/17
PAIRUI ELECTRONICS
Updated 2016-V1.0-1207
RND 315-00011:
Protection
Short circuit
Hiccuo mode, it will recover automatically after fault condition is removed
Over voltage
IS240-24: over voltage protection value 33V
IS240-48: over voltage protection value 66V
(1) When output voltage exceeds above over voltage protection value or reversal
voltage occurs, the protection will be started and the output voltage will be cut
off in order to protect the power supply;
(2) The power supply will recover after the power is turned on again
Over current
IS240-24: over current protection value 11A
IS240-48: over current protection value 5.5A
(1) When output voltage exceeds above over current protection value, the
protection will be started and the output voltage will be cut off in order to
protect the power supply;
(2) The power supply will recover automatically after the fault condition is
removed
Over
temperature
Over temperature protection value: 110±10℃
(1) When the ambient temperature exceeds above over temperature protection
value, the protection will be started and go into hiccup mode;
(2) The power supply will recover automatically after the fault condition is
removed
PRODUCT SPECIFICATION
din rail power supply
www.pairuigroup.com
Page:5/17
PAIRUI ELECTRONICS
Updated 2016-V1.0-1207
RND 315-00016
47-55
RND 315-00016: over voltage protecon value 66V
RND 315-00016: over voltage protecon value 5.5A