Datasheet
Protection
Short circuit Hiccup mode, it will recover automatically after fault condition is removed
Over voltage
RND 315-00007: over voltage protection value 20V
RND 315-00008: over voltage protection value 33V
(1) When output voltage exceeds above over voltage protection value or reversal voltage occurs, the
protection will be started and the output voltage will be cut off in order to protect the power supply;
(2) The power supply will recover after the power is turned on again
Over current
RND 315-00007: over current protection value 8A
RND 315-00008: over current protection value 4A
(1) When output voltage exceeds above over current protection value, the protection will be
started and the output voltage will be cut off in order to protect the power supply;
(2) The power supply will recover automatically after the fault condition is removed
Over
temperature
Over temperature protection value: 100±10℃
(1) When the ambient temperature exceeds above over temperature protection value, the protection
will be started and the output voltage will be cut off in order to protect the power supply;
(2) The power supply will recover after the power is turned on again