Datasheet
Output
Parameter Conditions MIN TYP MAX UNITS
Output voltage accuracy
2
%
Output voltage adjustment range
RND 315-00007
RND 315-00008
11-14
23-28
V
V
Output voltage can be adjusted within above range by V-ADJ. variable resistance inside of
the power supply. When output voltage exceeds the range, the power supply will be in
failure or get into over voltage protection mode. To avoid the case that the output voltage
is higher than rated voltage, output current should be used under rated current
Minimum load
0
A
Line regulation Vin from 100Vac to 240Vac
2
%
Load regulation Vout from min. to max.
3
%
Turn-on delay time Full load, Vin=115Vac 560 ms
Hold up time Full load, Vin=115Vac 20
ms